NaOHD and Hitergent Cassettes 의 안전성 경고

Department of Health에 따르면, 해당 안전성 경고 는 Hong Kong 에서 Roche Diagnostics GmbH 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 날짜
    2013-02-19
  • 사례 출판 날짜
    2013-02-19
  • 사례 국가
  • 사례 출처
    DH
  • 사례 출처 URL
  • 비고 / 경고
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • 데이터 추가 비고
    Medical Device Safety Alert
  • 원인
    Medical device safety alert: roche naohd and hitergent cassettes medical device manufacturer, roche diagnostics gmbh issued a medical device safety alert concerning the following products: naohd (for c702)- catalogue no.: 05172128 190; lot no.: 669088 and 663099 hitergent (for c702)- catalogue no.: 05172101 190; lot no.: 666210 according to roche, some of the lots listed above may have micro-leakage. internal investigation revealed that the frequency of the micro-leakage showed in 1 out of 8000 cassettes.  users are suggested to check whether the cellophane wrapping of the cassettes are wet before loading to the reagent manager. according to roche, all further product lots will undergo a 100% leakage check during the manufacturing process, and reimbursement or replacement can be offered in case of product leaking. according to the local supplier, roche diagnostics (hong kong) limited, the affected products have been distributed in hong kong. if you are in possession of the affected products, please contact your supplier for necessary actions. posted on 19 february 2013.

Device

  • 모델명 / 제조번호(시리얼번호)
  • 제품 설명
    Medical Device Safety Alert: Roche NaOHD and Hitergent Cassettes
  • Manufacturer

Manufacturer