NOxBOXi inhaled Nitric Oxide Delivery and Monitoring Device 의 안전성 경고

Department of Health에 따르면, 해당 안전성 경고 는 Hong Kong 에서 Bedfont Scientific 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 날짜
    2014-05-07
  • 사례 출판 날짜
    2014-05-07
  • 사례 국가
  • 사례 출처
    DH
  • 사례 출처 URL
  • 비고 / 경고
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • 데이터 추가 비고
    Medical Device Safety Alert
  • 원인
    Medical device safety alert: bedfont scientific noxboxi inhaled nitric oxide delivery and monitoring device the medicines and healthcare products regulatory agency (mhra), united kingdom posted a field safety notice concerning noxboxi inhaled nitric oxide delivery and monitoring device, manufactured by bedfont scientific. a conflict has been identified between the noxboxi regulators output and the cylinder status symbols shown on-screen. due to tolerances on the regulator output, some units may show a cylinder status as empty (red) when in fact they are full and some may show as full (green) when they are empty. with the latter a cylinder could empty without the operators knowledge, the system will switch over to the auxiliary/back-up cylinder, however when that is exhausted and system would then alarm “supply critical”. if another supply of gas is not available, sudden cessation of the therapy could occur. for patients dependent on this therapy, this failure could result in serious injury or death of the patient. the manufacturer advises affected users not to use the cylinder status icons on screen to determine gas supply. furthermore, the manufacturer is evaluating a firmware fix whereby the cylinder status tolerances are widened in order to eradicate the risk of cylinders showing as empty when they are full and full when they are empty. the regulators have a gas pressure gauge built into them which shows the cylinder status and this must be used only until a firmware fix is validated. for details, please refer to the following link:http://www.Mhra.Gov.Uk/safetyinformation/safetywarningsalertsandrecalls/fieldsafetynotices/con409264 if you are in possession of the affected product, please contact your supplier for necessary actions. posted on 07 may 2014.

Device

  • 모델명 / 제조번호(시리얼번호)
  • 제품 설명
    Medical Device Safety Alert: Bedfont Scientific NOxBOXi inhaled Nitric Oxide Delivery and Monitoring Device
  • Manufacturer

Manufacturer