On-Board Imager 의 안전성 경고

Department of Health에 따르면, 해당 안전성 경고 는 Hong Kong 에서 Varian Medical Systems 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 날짜
    2014-03-26
  • 사례 출판 날짜
    2014-03-26
  • 사례 국가
  • 사례 출처
    DH
  • 사례 출처 URL
  • 비고 / 경고
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • 데이터 추가 비고
    Medical Device Safety Alert
  • 원인
    Medical device safety alert: varian medical systems on-board imager medical device manufacturer, varian medical systems, has issued a medical device safety alert concerning its on-board imager. the manufacturer has received three reports that the shaft of the type 01 elbow motor for exact arms used in the on-board imager [obi] device have failed due to belt over-tensioning. this over-tensioning would have taken place during servicing. this failure would allow the exact arm to swing freely with gravity. no injuries have been reported to-date. only type 01 elbow motors are subject to these potential failures. according to the manufacturer, potential injury from the kv source striking a patient is dependent upon the anatomic site being treated and the height of the couch. the risk is greatest when the obi x-ray source is extended or retracted while it is above the patient. a geometric analysis determined that when the couch is positioned for a pelvis treatment [e.G., prostate treatments], the head of the patient could be positioned within the arc travelled by the kv source. if the kv source were to strike the patient’s head or chin, a fracture injury is possible. pelvic treatments with couch vertical positions less than 10 centimeters below isocenter have the highest potential for injury. the manufacturer instructs all affected users not to extend or retract the kv source arm when it is above a patient until the manufacturer inspects the obi exact arms. users should ensure that the gantry is positioned so that the kv source is lateral to, or underneath, the patient-couch prior to extending or retracting the arm. according to the manufacturer, the affected products were distributed in hong kong. if you are in possession of the affected products, please contact your supplier for necessary actions. posted on 26 march 2014.

Device

  • 모델명 / 제조번호(시리얼번호)
  • 제품 설명
    Medical Device Safety Alert: Varian Medical Systems On-Board Imager
  • Manufacturer

Manufacturer