OPTEASE Retrievable Vena Cava Filter 의 안전성 경고

Department of Health에 따르면, 해당 안전성 경고 는 Hong Kong 에서 Cordis 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 날짜
    2013-10-16
  • 사례 출판 날짜
    2013-10-16
  • 사례 국가
  • 사례 출처
    DH
  • 사례 출처 URL
  • 비고 / 경고
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • 데이터 추가 비고
    Medical Device Safety Alert
  • 원인
    Medical device safety alert: cordis optease retrievable vena cava filter medical device manufacturer, cordis (a johnson & johnson company), has initiated a field safety corrective action concerning optease retrievable vena cava filter. the affected catalogue numbers are 466f210a and 466f210b, and the affected lot numbers are 15960131 and below. cordis has identified a printing error on one unit of optease retrievable vena cava filter, in which the orientation arrow for the femoral approach was printed in the incorrect direction. the error resulted in the filter being implanted upside down, requiring an additional percutaneous procedure to retrieve the filter. implant of the opteaser retrievable vena cava filter with the hook oriented in the cranial direction can result in life threatening or serious injury including, but not limited to dissection, vessel perforation, migration of the filter with secondary damage to cardiac structures and ineffective pulmonary embolism prevention. there is no impact to the patient if the physician has successfully deployed and subsequently retrieved the filter. the manufacturer advises users to immediately identify, set aside and return all the affected products. according to the local supplier, the affected products were distributed in hong kong. for details, please refer to website of the medicine and healthcare products regulatory agency, united kingdom: http://www.Mhra.Gov.Uk/safetyinformation/safetywarningsalertsandrecalls/fieldsafetynotices/con321967 if you are in possession of the product, please contact your supplier for necessary actions. posted on 16 october 2013.

Device

  • 모델명 / 제조번호(시리얼번호)
  • 제품 설명
    Medical Device Safety Alert: Cordis OPTEASE Retrievable Vena Cava Filter
  • Manufacturer

Manufacturer