Perfusor Space Infusion Pump and Battery Pack 의 안전성 경고

Department of Health에 따르면, 해당 안전성 경고 는 Hong Kong 에서 B 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 날짜
    2013-11-22
  • 사례 출판 날짜
    2013-11-22
  • 사례 국가
  • 사례 출처
    DH
  • 사례 출처 URL
  • 비고 / 경고
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • 데이터 추가 비고
    Medical Device Safety Alert
  • 원인
    Medical device safety alert: b. braun perfusor space infusion pump and battery pack the medicines and healthcare products regulatory agency (mhra), united kingdom (uk) issued a medical device alert concerning perfusor space infusion pump (reference code 8713030) and battery pack (reference code 8713180) manufactured by b. braun medical ltd. according to the manufacturer, when an aged battery (4 years or older) is used, the pump may not have sufficient power to perform a syringe change, despite the battery indicator on the pump showing a full charge. the therapy could stop unexpectedly. this is because a syringe change requires a large current which may not be available if the battery has been significantly aged. b. braun explains that the problem does not arise if the pump is plugged into the mains and it does not affect running infusions. although there have been no reports of adverse incidents related to this matter, b. braun advises the affected clinical users and technical staff to: be aware that this issue presents a risk when the pump is used on battery only (for example during patient transfer) and is particularly relevant to patients on life sustaining or other critical medications. always have an additional pump available, for infusions of critical medications. remove the pump from use if this problem occurs and return the affected pumps with aged batteries for replacement. refer to the updated service documents for further details including how to identify the age of the battery and relevant test procedures. test or replace the affected batteries as soon as possible if the above mentioned problem occurs. test or replace the batteries during the next maintenance if the battery problem has not been reported so far. for details, please visit the following mhra website: http://www.Mhra.Gov.Uk/publications/safetywarnings/medicaldevicealerts/con341212 if you are in possession of the affected products, please contact your supplier for necessary actions. posted on 22 november 2013.

Device

  • 모델명 / 제조번호(시리얼번호)
  • 제품 설명
    Medical Device Safety Alert: B. Braun Perfusor Space Infusion Pump and Battery Pack
  • Manufacturer
    B

Manufacturer

B