Pinnacle3 Radiation Treatment Planning System 의 안전성 경고

Department of Health에 따르면, 해당 안전성 경고 는 Hong Kong 에서 Philips Healthcare 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 날짜
    2014-08-08
  • 사례 출판 날짜
    2014-08-08
  • 사례 국가
  • 사례 출처
    DH
  • 사례 출처 URL
  • 비고 / 경고
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • 데이터 추가 비고
    Medical Device Safety Alert
  • 원인
    Medical device safety alert: philips healthcare pinnacle3 radiation treatment planning system medical device manufacturer, philips healthcare, has issued a field safety notice (fsn) concerning its pinnacle3 radiation treatment planning system with software version 9 0, 9 2 9 4, and 9 6. the issue occurs under certain specific conditions where the user modifies a contour in a density-overridden roi (region of interest with density set to a specific value) in a computed plan. dose is subsequently invalidated and the user may recompute the dose. in this case, the density can be replaced by the ct number from the ct to density table when recomputed resulting in an incorrect dose and the monitor units (mu) may then be much higher than originally planned. the user may continue, and save the plan with incorrect dose. when reopening the plan, the density is reported as the correct value but the dose remains incorrect based on the prior incorrect value for density. this issue could create an incorrect mu calculation, resulting in an incorrect dose to the target or other structures. if the situation is noticed prior to completion of the treatment, the incorrect beam could be corrected to give the correct total dose.¬ the manufacturer will upgrade all the affected units to version 9.8 and it recommends users to always use version 9.8 or above for patient planning. if users do not have version 9.8 installed, they should contact local representative. furthermore, the fsn should be placed in instructions for use until otherwise notified. according to the local supplier, the affected products were distributed in hong kong. if you are in possession of the products, please contact your supplier for necessary actions. posted on 8 aug 2014.

Device

  • 모델명 / 제조번호(시리얼번호)
  • 제품 설명
    Medical Device Safety Alert: Philips Healthcare Pinnacle3 Radiation Treatment Planning System