Puritan Bennett 840 Ventilator 의 안전성 경고

Department of Health에 따르면, 해당 안전성 경고 는 Hong Kong 에서 Covidien 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 날짜
    2014-06-10
  • 사례 출판 날짜
    2014-06-09
  • 사례 국가
  • 사례 출처
    DH
  • 사례 출처 URL
  • 비고 / 경고
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • 데이터 추가 비고
    Medical Device Safety Alert
  • 원인
    Medical device safety alert: covidien puritan bennett 840 ventilator the australia therapeutic goods administration (tga) posted a medical device safety alert concerning puritan bennett 840 ventilator manufactured by covidien. the affected ventilator serial numbers are 3510102854, 3510102868, 3510102839, 3510102853, 3510102849, 3510102848 and 3510102852, and the serial numbers of the affected power supply units are 39302, 40221, 40355, 40465, 40324, 40327 and 40450. the manufacturer has received customer reports of the loss of graphical user interface (gui) display information while the ventilator continues to provide breath support. customer reports describe the gui display screens (both upper and lower) becoming blank during patient use. this event interferes with the clinician's ability to view and/or change ventilator setting or clinician-set patient alarm parameters. loss of gui display due to a power supply unit (psu) failure is demonstrated by the ventilator entering a “gui inop” state i.E. if the breath delivery unit (bdu) loses communication with the gui, the bdu recognises this and enters a “gui inop” state. it initiates the appropriate alarm consisting of a visible alarm indicated by the illumination of the “gui inop” red light on the bdu and a high-priority audible alarm. the source of the psu voltage loss is a specific circuit responsible solely for the gui central processing unit voltages. a representative from the manufacturer will perform an inspection of affected ventilator(s) to determine if it has the affected component and if so, will replace the psu immediately. if users encounter a loss of display, they are advised to verify the patient’s respiratory and physiological stability i.E. confirm the patient is receiving ventilatory support by observation of the expansion and contraction of the patient’s chest and assess current patient status by review of other monitoring parameters (e.G., oxygen saturation, heart rate, blood pressure, etc). also, the manufacturer advises users to promptly transfer the patient to an alternate ventilator in a manner consistent with the institutional protocol and remove the affected ventilator from use until it has been serviced. for details, please refer to tga website: http://www.Tga.Gov.Au/sara/arn-detail.Aspx?k=rc-2014-rn-00618-1 if you are in possession of the affected products, please contact your supplier for necessary actions. posted on 9 june 2014.

Device

  • 모델명 / 제조번호(시리얼번호)
  • 제품 설명
    Medical Device Safety Alert: Covidien Puritan Bennett 840 Ventilator
  • Manufacturer

Manufacturer

  • 제조사 모회사 (2017)
  • 제조사 의견
    “If our surveillance systems identify a potential performance issue, our personnel promptly evaluate the problem, including, when appropriate, conducting root cause investigations and internal testing to assess whether the product continues to meet specifications and defined performance criteria,” Medtronic told ICIJ in a statement. “In some cases, based on this evaluation, Medtronic may determine that a recall is necessary.” The company said that it communicates with healthcare providers and/or patients and provide recommendations to address such issues. Medtronic noted that these communications can include letters, emails, calls, press releases, physician notifications and social media postings, as well as informing the FDA and other regulators of the actions.
  • Source
    DH