Quick connect scales used with Maxi Sky 2 ceiling lifts 의 안전성 경고

Department of Health에 따르면, 해당 안전성 경고 는 Hong Kong 에서 ArjoHuntleigh 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 날짜
    2018-02-23
  • 사례 출판 날짜
    2018-02-23
  • 사례 국가
  • 사례 출처
    DH
  • 사례 출처 URL
  • 비고 / 경고
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • 데이터 추가 비고
    Medical Device Safety Alert
  • 원인
    Medical device safety alert: arjohuntleigh quick connect scales used with maxi sky 2 ceiling lifts medical device manufacturer, arjohuntleigh, has issued a medical device safety alert concerning its quick connect scales used with maxi sky 2 ceiling lifts the affected products are as follows: - product codes: a) 700-19485; b) 700-19490 serial numbers: a) from 300146551 up to 300220716; b) from 300142013 up to 300219867 manufactured between june 2016 and november 2017. the manufacturer has received a limited number of complaints where it was mentioned there was a disconnection occurrence of the spreader bar from the quick connect scale. according to the manufacturer, the hazard could be replicated under a specific sequence of events. if a spreader bar detaches from the quick connect attachment of the scale, a patient can fall and may lead to a potential risk of injury. the manufacturer shall arrange local service technician to visit the facilities to carry out the upgrade of the scales. the affected customers are requested to ensure that all caregivers and users of the affected devices are made aware of the field safety notice and all listed devices at their facility are available to be corrected during service technician visit. the device may stay in use until the upgrade will be performed, on the condition that the following instructions are carefully followed: before initiating the patient transfer, once the patient is installed in the sling and the weight is gradually taken up, always check that the scale quick connect lower attachment is aligned with the spreader bar quick connect. if not, do not proceed with the patient transfer, lower the patient, remove completely the patient weight on the scale and then reinstall adequately the spreader bar attachment. according to the local supplier, the affected products are distributed in hong kong. if you are in possession of the affected products, please contact your supplier for necessary actions. posted on 23 february 2018.

Device

  • 모델명 / 제조번호(시리얼번호)
  • 제품 설명
    Medical Device Safety Alert: ArjoHuntleigh Quick connect scales used with Maxi Sky 2 ceiling lifts
  • Manufacturer

Manufacturer