RayStation 의 안전성 경고

Department of Health에 따르면, 해당 안전성 경고 는 Hong Kong 에서 RaySearch Laboratories 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 날짜
    2017-11-24
  • 사례 출판 날짜
    2017-11-24
  • 사례 국가
  • 사례 출처
    DH
  • 사례 출처 URL
  • 비고 / 경고
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • 데이터 추가 비고
    Medical Device Safety Alert
  • 원인
    Medical device safety alert: raysearch laboratories raystation medical device manufacturer, raysearch laboratories, has issued a medical device safety alert concerning its treating planning system, raystation. the affected devices are: raystation 3.5, raystation 4.0, raystation 4.5, raystation 4.7, raystation 5, raystation 6, rayplan 1 (raystation 4.9) and rayplan 2 (raystation 6). electron dose calculation in raystation uses a monte carlo dose engine, where a large number of particles are simulated. each simulated particle is called a history, adding to the simulated dose. the number of histories can be adjusted for each dose calculation. generally, a higher number of histories leads to a better dose accuracy due to lower statistical uncertainty, but adds to the calculation time. in beam modeling, using a higher number of histories may also be desired to determine an appropriate normalization value for commissioning the treatment machine. when starting the dose calculation, the data variable representing the number of histories is erroneously converted to a number format which cannot handle sufficiently large values. this means that when a very large number of histories is requested, the monte carlo dose engine may use a lower number of histories than requested. at the end of the dose calculation, the resulting dose is divided by the intended number of histories. this leads to a calculated dose that is lower than the actual dose. the shape of the dose distribution will be correct but the absolute dose level will be wrong. the error can arise during treatment planning in raystation and in rayplan, as well as during beam commissioning in rayphysics and in rayplanphysics. when the number of histories during treatment planning is above the limit, the computed dose is underestimated which leads to overdosage. commissioning a machine with a normalization value determined by an erroneous calculation would scale the monitor units so that too few monitor units are prescribed. this results in an underdosage to all patients, regardless of the number of histories used in treatment planning. if the large number of histories which is required to trigger the error is used, this would result in very long calculation times. this large number of histories is also well above the required number of histories to get a clinically acceptable dose accuracy. for an individual treatment plan, the error could be detected by common clinical knowledge of the expected dose per monitor unit relationship for electron beams or by secondary calculations. for beam commissioning, the error could be detected by validation of the beam model. the manufacturer advises affected users to take the following actions:- do not use a number of histories above 6 million for electron dose calculation. inspect all commissioned electron beam models for any applicator calculated with greater than 6 million histories. according to the manufacturer, the affected products are distributed in hong kong. if you are in possession of the affected products, please contact your supplier for necessary actions. posted on 24 november 2017.

Device

  • 모델명 / 제조번호(시리얼번호)
  • 제품 설명
    Medical Device Safety Alert: RaySearch Laboratories RayStation
  • Manufacturer

Manufacturer