Relay and Relay NBS Thoracic Stent-Graft Systems 의 안전성 경고

Department of Health에 따르면, 해당 안전성 경고 는 Hong Kong 에서 Bolton Medical 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 날짜
    2014-08-12
  • 사례 출판 날짜
    2014-08-12
  • 사례 국가
  • 사례 출처
    DH
  • 사례 출처 URL
  • 비고 / 경고
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • 데이터 추가 비고
    Medical Device Safety Alert
  • 원인
    Medical device safety alert: bolton medical relay and relay nbs thoracic stent-graft systems medical device manufacturer, bolton medical, has issued a field safety notice (fsn) concerning its relay and relay nbs thoracic stent-graft systems with the following information: references: 28m3###########x and 28n2###########x all lots manufactured prior to august 2014 according to the fsn, it has been observed in a small number of cases that the inner secondary sheath may not fully exit the outer primary sheath upon reaching the black line. in this situation, the distal end of the stent-graft will also remain within the outer primary sheath. failure to recognize this condition prior to deployment can lead to deployment difficulty or deployment failure. there is no impact on devices already implanted. the manufacturer is recommending the following additional verification steps prior to proceeding to the final stent-graft positioning and deployment: 1) upon reaching the intended proximal landing zone, visually confirm that the distal stent marker bands can be seen approximately 2cm outside of the outer primary sheath. 2) if the distal stent marker bands do not appear to have exited the outer primary sheath, while in position 1, hold the gray deployment grip stationary while pulling back on the black stationary grip until the distal stent marker bands have exited the outer primary sheath by approximately 2cm. according to the local supplier, the affected products were distributed in hong kong. if you are in possession of the products, please contact your supplier for necessary actions. posted on 12 aug 2014.

Device

  • 모델명 / 제조번호(시리얼번호)
  • 제품 설명
    Medical Device Safety Alert: Bolton Medical Relay and Relay NBS Thoracic Stent-Graft Systems
  • Manufacturer

Manufacturer