Sarns Disposable Centrifugal Pump 의 안전성 경고

Department of Health에 따르면, 해당 안전성 경고 는 Hong Kong 에서 Terumo Cardiovascular Systems 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 날짜
    2014-04-25
  • 사례 출판 날짜
    2014-04-25
  • 사례 국가
  • 사례 출처
    DH
  • 사례 출처 URL
  • 비고 / 경고
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • 데이터 추가 비고
    Medical Device Safety Alert
  • 원인
    Medical device safety alert: terumo cvs sarns disposable centrifugal pump medical device manufacturer, terumo cardiovascular systems (cvs) corporation has issued a field safety notice concerning its sarns disposable centrifugal pumps. the manufacturer has received complaints of sarns disposable centrifugal pumps leaking due to a crack in the molded separator. the manufacturer’s investigation determined that two factors must be present to cause a leak in the molded separator: degradation in the strength of the separator material: exposure to extremely low temperatures can degrade the strength of the separator’s polycarbonate resin. contraction of two dissimilar materials: the polycarbonate separator and stainless steel bearing can contract at different rates while exposed to extremely low temperatures, potentially causing the white separator to crack. product was exposed to these temperatures in the course of transport during an unusually harsh winter. these temperatures were outside a clinically relevant operating range. if a pump leaks during priming, the centrifugal pump can be changed out prior to initiating cardiopulmonary bypass (cpb) with no delays in the surgical procedure. if a centrifugal pump leaks while the patient is on cpb, the manufacturer advises user to follow the instructions for use (ifu) and replace the centrifugal pump. in any time a centrifugal pump fails when being used as an arterial pump, arterial flow to the patient is interrupted during the change-out procedure. in addition, a stopped centrifugal pump can result in retrograde flow from the patient to the circuit. potential patient impact includes air embolism, blood loss, infection and/or an interruption in the cardiopulmonary bypass support for an indeterminate amount of time. in addition, replacing a centrifugal pump during cpb necessitates that the replacement device connections be made with wet connections which do not have the same security as a dry connection. this can increase the risk of a tubing disconnection. the manufacturer advises users to stop using sarns disposable centrifugal pumps from the affected single, sterile centrifugal pump lots or cardiovascular procedure kit lots. the manufacturer will also replace or credit unused affected centrifugal pumps. according to the local supplier, the affected products were not distributed in hong kong. if you are in possession of the products, please contact your supplier for necessary actions. posted on 25 april 2014.

Device

  • 모델명 / 제조번호(시리얼번호)
  • 제품 설명
    Medical Device Safety Alert: Terumo CVS Sarns Disposable Centrifugal Pump