Sarns Modular Perfusion System 8000 의 안전성 경고

Department of Health에 따르면, 해당 안전성 경고 는 Hong Kong 에서 Terumo Cardiovascular Systems 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 날짜
    2012-11-02
  • 사례 출판 날짜
    2012-11-02
  • 사례 국가
  • 사례 출처
    DH
  • 사례 출처 URL
  • 비고 / 경고
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • 데이터 추가 비고
    Medical Device Safety Alert
  • 원인
    Medical device safety alert: terumo sarns modular perfusion system 8000 medical device manufacturer, terumo cardiovascular systems corporation (terumo cvs) has initiated a field safety corrective action concerning sarns modular perfusion system 8000. terumo cvs has received multiple reports since 2007 of various malfunctions of the power distribution and battery back-up systems for the sarns modular perfusion system 8000. very few of the reports occurred during cardiopulmonary bypass; the majority of the malfunctions occurred during set-up or were reported during routine preventative maintenance. the malfunctions can be broadly categorized as loss of wall (ac) power, battery back-up malfunction and battery status indicator malfunction. terumo cvs’ initial investigation found that the operator's manual for the sarns system 8000 does not provide sufficient instruction on how to respond to a flashing red indicator light and how to ensure the function of the battery back-up prior to each case. there were no known reports of patient injury as a result of these issues. the manufacturer is informing sarns system 8000 users of the risks associated with these malfunctions and providing an addendum to inform the user with additional instructions. according to the local supplier, the affected products were not distributed in hong kong. if you are in possession of the product, please contact your supplier for necessary actions. posted on 2 november 2012.

Device

  • 모델명 / 제조번호(시리얼번호)
  • 제품 설명
    Medical Device Safety Alert: Terumo Sarns Modular Perfusion System 8000
  • Manufacturer

Manufacturer