Select 3D and Select CAP Arterial Cannula 의 안전성 경고

Department of Health에 따르면, 해당 안전성 경고 는 Hong Kong 에서 Medtronic 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 날짜
    2014-02-11
  • 사례 출판 날짜
    2014-02-11
  • 사례 국가
  • 사례 출처
    DH
  • 사례 출처 URL
  • 비고 / 경고
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • 데이터 추가 비고
    Medical Device Safety Alert
  • 원인
    Medical device safety alert: medtronic select 3d and select cap arterial cannula the medicines and healthcare products regulatory agency (mhra), united kingdom posted a field safety notice concerning all models of select 3d and select cap arterial cannula product families manufactured by medtronic due to reports of the cannula body splitting near the suture collar.. the affected model numbers are 78618, 78620, 78622, 78624, 78718, 78720, 78722, cb78722, 78724, 78818, 78820, 78822, 78920, 78922, 78924, 3y90r3 and c300901b. since january 2012, the manufacturer has received nine such reported events which represent a 0.06% occurrence rate. of these, one was associated with a patient death and one other was associated with serious injury. according to the manufacturer, potential patient harms resulting from this type of splitting may include: the delivery of inadequate blood flow, possibly resulting in ischemia or inadequate perfusion. difficulty in inserting/removing the cannula tip, possibly resulting in a procedural delay, vessel damage, dissection or other complications that may contribute to patient death. the manufacturer advises users to identify and quarantine all affected products and return them to the manufacturer. for details, please refer to the following link:http://www.Mhra.Gov.Uk/safetyinformation/safetywarningsalertsandrecalls/fieldsafetynotices/con371783 according to the local supplier, the affected products were not distributed in hong kong. if you are in possession of the affected product, please contact your supplier for necessary actions. posted on 11 february 2014.

Device

  • 모델명 / 제조번호(시리얼번호)
  • 제품 설명
    Medical Device Safety Alert: Medtronic Select 3D and Select CAP Arterial Cannula
  • Manufacturer

Manufacturer

  • 제조사 모회사 (2017)
  • 제조사 의견
    “If our surveillance systems identify a potential performance issue, our personnel promptly evaluate the problem, including, when appropriate, conducting root cause investigations and internal testing to assess whether the product continues to meet specifications and defined performance criteria,” Medtronic told ICIJ in a statement. “In some cases, based on this evaluation, Medtronic may determine that a recall is necessary.” The company said that it communicates with healthcare providers and/or patients and provide recommendations to address such issues. Medtronic noted that these communications can include letters, emails, calls, press releases, physician notifications and social media postings, as well as informing the FDA and other regulators of the actions.
  • Source
    DH