Short Term Acute Dialysis Catheters 의 안전성 경고

Department of Health에 따르면, 해당 안전성 경고 는 Hong Kong 에서 Joline 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 날짜
    2013-06-17
  • 사례 출판 날짜
    2013-06-17
  • 사례 국가
  • 사례 출처
    DH
  • 사례 출처 URL
  • 비고 / 경고
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • 데이터 추가 비고
    Medical Device Safety Alert
  • 원인
    Medical device safety alert: joline short term acute dialysis catheters the medicines and healthcare products regulatory agency (mhra), united kingdom posted a field safety notice concerning short term acute dialysis catheters, manufactured by joline. the affected products were manufactured from jun 2012 to feb 2013. in the course of continuous market surveillance, the manufacturer became aware that occasionally there could be an increased risk of hairline cracks at the connectors of these catheters. it was observed that during the application of the catheter crack formation sporadically occurred. although there has been no patient endangering so far, blood loss cannot be excluded. by means of optimized manufacturing processes and improvements of the design, the mechanical and chemical resistance could be enhanced. until these measures are completely implemented, the manufacturer asks customers to waive alcoholic disinfectants, in no case connect before complete drying as already indicated in the instructions for use and avoid excessive forces when connecting as well as ensure a regular and frequent control of the connectors, and securely clamp affected catheters with the mounted safety clamp and change the catheter. furthermore, the manufacturer advises distributors to stop selling the affected products. for details, please refer to mhra website http://www.Mhra.Gov.Uk/safetyinformation/safetywarningsalertsandrecalls/ fieldsafetynotices/con286760 if you are in possession of the product, please contact your supplier for necessary actions. posted on 17 june 2013.

Device

  • 모델명 / 제조번호(시리얼번호)
  • 제품 설명
    Medical Device Safety Alert: Joline Short Term Acute Dialysis Catheters
  • Manufacturer

Manufacturer