Sophos 151, Sophos 155 and Helios 300 implantable pacemakers 의 안전성 경고

Department of Health에 따르면, 해당 안전성 경고 는 Hong Kong 에서 Medico 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 날짜
    2011-01-27
  • 사례 국가
  • 사례 출처
    DH
  • 사례 출처 URL
  • 비고 / 경고
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • 데이터 추가 비고
    Press release
  • 원인
    Serious safety concern on some medico implantable pacemakersthe department of health (dh) today (january 27) warned the public that a group of implantable pacemakers run the serious risk that they may not function. dh, through its routine surveillance on medical devices, noticed that uk's medicines and healthcare products regulatory agency (mhra) has made an alert on a report by the italian manufacturer medico that a group of its implantable cardiac stimulators, sophos 151, sophos 155 and helios 300, might fail to function. medico discovered this during a routine follow-up and on analysis of sophos 151 pacemaker serial number mdaa473, found that the malfunctioning was because of intermittent instability of the electrical continuity of some inner substrate connections.? a dh spokesman remarked that although the incidence of failure is low, quoted to be 0.013%, and thus far there is neither record of marketing or report of field event in hong kong, the dreaded consequence and that there may be occasional patients here who have somehow obtained the devices overseas are what cause the publication of this statement.? the serial numbers of the medico pacemakers involved are - a)? sophos 151, serial numbers from mdaa378 to mdaa383, from mdaa385 to mdaa411, from mdaa413 to mdaa421, mdaa423, mdaa424, from mdaa426 to mdaa448, from mdaa450 to mdaa464, from mdaa466 to mdaa472, from mdaa474 to mdaa483, from mdaa496 to mdaa506; b)? sophos 155 with serial numbers from mdfa222 to mdfa234, from mdfa236 to mdfa312; and c)? helios 300 with serial numbers from mb3a111 to mb3a120. while dh will continue to check with medico and mhra about the export of the incriminated products to hong kong besides monitoring the development of the issue, the spokesman said: "any member of the public who have been implanted with any of the affected products should consult their healthcare workers for advice as soon as possible". meanwhile, dh has also informed all public and private hospitals and medical professional associations about the matter and advised them to remain vigilant. ends/thursday, january 27, 2011.

Device

  • 모델명 / 제조번호(시리얼번호)
  • 제품 설명
    Press release: Serious safety concern on some Medico implantable pacemakers
  • Manufacturer

Manufacturer