Spring Arm of surgical lights 의 안전성 경고

Department of Health에 따르면, 해당 안전성 경고 는 Hong Kong 에서 Stryker Communications 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 날짜
    2012-10-31
  • 사례 출판 날짜
    2012-10-31
  • 사례 국가
  • 사례 출처
    DH
  • 사례 출처 URL
  • 비고 / 경고
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • 데이터 추가 비고
    Medical Device Safety Alert
  • 원인
    Medical device safety alert: stryker spring arm the medicines and healthcare products regulatory agency (mhra), united kingdom posted a field safety notice concerning spring arm of surgical lights, manufactured by stryker communications. the affected part numbers are as follows: 0682000112 spring arm, light 12-18kg 0682000211 flat panel spring arm, ondal suspension, 15-21kg 0682000212 flat panel spring arm, ondal susp., 12-18kg 0682000226 spring arm, 3.5-7kg, navigation 0682000228 spring arm, light 9-15kg 0682001062 pkg eds light suspension central axis 5p/fp 0682001270 9-pole spring arm, ac 2000, 15-21 kg 0682001274 5-pole spring arm ac 2000 15-21 kg 0682400034 flat panel spring arm, eds suspension, 15-21kg 0682400059 universal yoke spring arm retrofit kit 0682400059i universal yoke & spring arm retrofit kit, int 0682400151 low ceiling spring arm, 5p side mount 0682400152 low ceiling spring arm, 9p side mount 0682400169 5-pole spring arm ac 2000 9-15kg, cardinal 0682400207 standard spring arm with bearing, 5p 0682400208 standard spring arm with bearing, 9p 0682400365 flat panel spring arm with eha adapter bearing the manufacturer has identified that there is a low likelihood of incomplete engagement of the spring arm circlip during service or replacement of the spring arm. if the spring arm circlip is not fully seated, the spring arm could separate and fall along with the surgical lights, monitors or navigation cameras mounted to the end of the spring arm which may lead to serious injury. this action affects devices which were manufactured between june 2004 and february 2012 and is restricted to specific serial numbers only. to-date, there have been no serious injuries reported from the incomplete engagement of the spring arm circlip. furthermore, the manufacturer advised that: all affected users should inspect their inventory to see if the affected devices needed to be replaced. use of the spring arm should only be continued after confirmation that there is not a 10 mm gap or greater at the spring arm interface. the manufacturer will also visit the affected users to inspect, and if necessary, correct the spring arm circlip. for details, please refer to mhra website http://www.Mhra.Gov.Uk/safetyinformation/safetywarningsalertsandrecalls/fieldsafetynotices/con195935 if you are in possession of the product, please contact your supplier for necessary actions. posted on 31 october 2012.

Device

  • 모델명 / 제조번호(시리얼번호)
  • 제품 설명
    Medical Device Safety Alert: Stryker Spring Arm
  • Manufacturer

Manufacturer

  • 제조사 모회사 (2017)
  • Source
    DH