TumorLOC in Brilliance CT Big Bore, Extended Brilliance Workspace, GEMINI LXL, GEMINI TF 16, GEMINI TF 64, GEMINI TF Big Bore 의 안전성 경고

Department of Health에 따르면, 해당 안전성 경고 는 Hong Kong 에서 Philips Medical Systems 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 날짜
    2012-11-13
  • 사례 출판 날짜
    2012-11-13
  • 사례 국가
  • 사례 출처
    DH
  • 사례 출처 URL
  • 비고 / 경고
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • 데이터 추가 비고
    Medical Device Safety Alert
  • 원인
    Medical device safety alert: philips tumorloc in brilliance ct big bore, extended brilliance workspace, gemini lxl, gemini tf 16, gemini tf 64, gemini tf big bore medical device manufacturer, philips medical systems, has issued a medical device safety alert concerning tumorloc in brilliance ct big bore, extended brilliance workspace (ebw), gemini lxl, gemini tf 16, gemini tf 64 and gemini tf big bore. the tumorloc application has the capability to generate intensity projection datasets from respiratory gated data. a circumstance has been identified where these generated datasets are flipped and incorrectly labeled left to right when they are saved to disk. this problem occurs only if all of the following circumstances are met: 1. the respiratory gated series are loaded into tumorloc along with a non-gated (free breathing) series, and 2. the data loaded into tumorloc is generated with specific patient orientations, and reconstructed with specific view conventions (see below). head first prone / right on left head first prone / view from feet feet first supine / view from bed feet first prone / view from feet if the flipped intensity projection dataset is used in the radiation therapy workflow, then this may result in unintended delivery of radiation to healthy tissue and/or failure to deliver radiation to the target lesion. the manufacturer advised the affected users to maintain a copy of the field safety notice(fsn) with the equipment instructions for use and follow the additional instructions mentioned in the fsn until the software correction is issued. according to the local supplier, the affected devices were distributed in hong kong. if you are in possession of the affected product, please contact your supplier for necessary actions. posted on 13 november 2012.

Device

  • 모델명 / 제조번호(시리얼번호)
  • 제품 설명
    Medical Device Safety Alert: Philips TumorLOC in Brilliance CT Big Bore, Extended Brilliance Workspace, GEMINI LXL, GEMINI TF 16, GEMINI TF 64, GEMINI TF Big Bore