UniCel DxH Slidemaker Stainer Coulter Cellular Analysis System 의 안전성 경고

Department of Health에 따르면, 해당 안전성 경고 는 Hong Kong 에서 Beckman Coulter 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 날짜
    2016-08-11
  • 사례 출판 날짜
    2016-08-11
  • 사례 국가
  • 사례 출처
    DH
  • 사례 출처 URL
  • 비고 / 경고
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • 데이터 추가 비고
    Medical Device Safety Alert
  • 원인
    Medical device safety alert: beckman coulter unicel dxh slidemaker stainer coulter cellular analysis system medical device manufacturer, beckman coulter, has issued a medical device safety alert concerning its unicel dxh slidemaker stainer coulter cellular analysis system [part number reference 775222; all software revisions]. the manufacturer has received and confirmed a report of a fire within the stainer module of a customer’s dxh slidemaker stainer. the fire was fully contained within the stainer module. the event was preceded by a significant increase in the frequency of the automatic top-off of the module’s methanol bath. users are being advised to discontinue use of the stainer module to reduce the potential for flammable liquids coming into contact with electrical components in the stainer module possibly causing a fire. the manufacturer is investigating the reported incident to determine the root cause, and define and implement required corrective and preventive actions. the manufacturer is advising users to: immediately discontinue use of the stainer module; drain all liquids from the stainer module; follow the directions provided for placing the stainer module in extended shutdown and disabling the stainer.; and a manufacturer’s service representative will schedule a visit to modify the stainer module so that it remains disabled and cannot be used until further corrective action is implemented. according to the local supplier, the affected products are distributed in hong kong. if you are in possession of the affected products, please contact your supplier for necessary actions. posted on 11 august 2016.

Device

  • 모델명 / 제조번호(시리얼번호)
  • 제품 설명
    Medical Device Safety Alert: Beckman Coulter UniCel DxH Slidemaker Stainer Coulter Cellular Analysis System