VIDAS FSH 의 안전성 경고

Department of Health에 따르면, 해당 안전성 경고 는 Hong Kong 에서 BioMérieux 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 날짜
    2018-03-09
  • 사례 출판 날짜
    2018-03-09
  • 사례 국가
  • 사례 출처
    DH
  • 사례 출처 URL
  • 비고 / 경고
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • 데이터 추가 비고
    Medical Device Safety Alert
  • 원인
    Medical device safety alert: biomérieux, vidas fsh medical device manufacturer, biomérieux, has issued a medical device safety alert concerning its vidas fsh. the affected products are identified as below: product references: a) 30407; b) 30407-01. lot numbers: a) 1005888220, 1006006370, 1006080890, 1006094700 and 1006214640; b) 1005888210. the manufacturer has received several complaints for invalid calibration with low calibrator s1 while using vidas fsh reference 30407 / 30407-01. tests performed in-house confirmed a decrease of the strips signal overtime for the impacted lots. according to the manufacturer, the defect was highlighted with complaints for invalid calibration, but concerns all testing performed (calibration and patient’s samples testing). the investigation concluded that this could have an impact on patient results. there are two possible situations as following: in case of invalid calibration: an error message appears and it will not be possible to perform further testing with the concerned lot. in this context, the risk for patients is a delayed result due to invalid calibration. in case of valid calibration: false results (falsely overestimated or falsely underestimated results) may happen. affected users are requested to destroy the impacted lots. for tests previously performed using the impacted lots of vidas fsh, the affected users are asked to discuss any concerns they may have regarding previously reported patient results obtained with the clinicians to determine the appropriate course of action. results should be reviewed and interpreted within the overall clinical context. according to the local supplier, the affected products are distributed in hong kong. if you are in possession of the affected products, please contact your supplier for necessary actions. posted on 9 march 2018.

Device

  • 모델명 / 제조번호(시리얼번호)
  • 제품 설명
    Medical Device Safety Alert: BioMérieux, VIDAS FSH
  • Manufacturer

Manufacturer