ADVIA 560 Hematology Systems 의 리콜

U.S. Food and Drug Administration에 따르면, 해당 리콜 는 United States 에서 Siemens Healthcare Diagnostics, Inc. 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

의료기기에 문제가 생겼을 경우 제조사가 이를 바로잡거나 시장에서 회수하는 조치를 말한다. 회수(Recall)는 의료기기에 결함이 있거나, 건강에 위협이 되거나, 또는 결함도 있고 건강에도 위협이 될 경우에 발생한다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Recall
  • 사례 ID
    75652
  • 사례 위험등급
    Class 2
  • 사례 연번
    Z-0723-2017
  • 사례 시작날짜
    2016-10-21
  • 사례 상황
    Terminated
  • 사례 국가
  • 사례 종료 날짜
    2018-06-07
  • 사례 출처
    USFDA
  • 사례 출처 URL
  • 비고 / 경고
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • 데이터 추가 비고
    Counter, differential cell - Product Code GKZ
  • 원인
    Siemens is investigating an issue which may cause an incorrect result to be reported. siemens received two reports of multiple discordant records for the same sample id in the advia 560 hematology system database that occurred during the installation of the systems. the database should only contain one record of a sample id number for any given time and date. if there are multiple records for the same sample id, it is possible that multiple results may be manually or automatically sent to the laboratory information system (lis), printed or displayed on the results report screen.
  • 조치
    An Urgent Medical Device Correction Letter HI17-02.A.US (dated October 21, 2016) and Response Form were sent to US Customers via Federal Express. An Urgent Field Safety Notice was sent to customers outside the US on October 21, 2016, (distribution is determined at the country level). The letters instruct customers to contact their local Siemens technical support representative if they obtain multiple results for one Sample ID. It also informs the customer what to do if the ADVIA 560 Hematology System generates any of the six error messages listed in the letter. For further questions, please call (312) 275-7795.

Device

  • 모델명 / 제조번호(시리얼번호)
    All serial numbers of ADVIA 560 Hematology Systems
  • 의료기기 분류등급
  • 의료기기 등급
    2
  • 이식된 장치?
    No
  • 유통
    Worldwide Distribution - US Distribution to the states of including Puerto Rico and : CA, CO, FL, IL, MI, NJ, NY, OH, TX, WA, WI, WI and WY., and to the countries of : Angola, Australia, Belgium, Brazil, Canada, Chile, Colombia, Croatia, Czech Republic, Egypt, France, Germany, Greece, India, Italy, Japan, Kenya, Malaysia, Mexico, Myanmar, Netherlands, Norway, Pakistan, Portugal, Saudi Arabia, Slovenia, Spain, Switzerland, Turkey, Uganda, United Kingdom, Vietnam.
  • 제품 설명
    ADVIA 560 Hematology Systems, Siemens Material Number (SMN) 11170842, IVD.
  • Manufacturer

Manufacturer

  • 제조사 주소
    Siemens Healthcare Diagnostics, Inc., 511 Benedict Ave, Tarrytown NY 10591-5005
  • 제조사 모회사 (2017)
  • Source
    USFDA