Carestream Vue PACS; MX WEB SVR W/3 MXRAD LIC15K EXAMS 의 리콜

U.S. Food and Drug Administration에 따르면, 해당 리콜 는 United States 에서 Carestream Health Inc. 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

의료기기에 문제가 생겼을 경우 제조사가 이를 바로잡거나 시장에서 회수하는 조치를 말한다. 회수(Recall)는 의료기기에 결함이 있거나, 건강에 위협이 되거나, 또는 결함도 있고 건강에도 위협이 될 경우에 발생한다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Recall
  • 사례 ID
    66306
  • 사례 위험등급
    Class 2
  • 사례 연번
    Z-0225-2014
  • 사례 시작날짜
    2013-09-16
  • 사례 출판 날짜
    2013-11-13
  • 사례 상황
    Terminated
  • 사례 국가
  • 사례 종료 날짜
    2015-12-21
  • 사례 출처
    USFDA
  • 사례 출처 URL
  • 비고 / 경고
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • 데이터 추가 비고
    System, image processing, radiological - Product Code LLZ
  • 원인
    Carestream health, inc. has issued a recall when using the carestream client workstation where under very specific conditions, some images from multi-slice studies such as ct and mr may not load into the viewer application due to a software problem.
  • 조치
    Carestream sent an Urgent Medical Device Recall letter dated September 13, 2013, to all affected customers via Fed Ex on September 16, 2013, informing them that a software problem may have the potential to occur under certain conditions when using the CARESTREAM Client Workstation. When certain conditions are met, it appears that the child background process completes its tasks before the parent process and as a result the parent process considers its work done and terminates. In the event that a software problem does occur, the scan may not be fluent or the image numbers may not be sequential. A software patch is currently being deployed by Carestream Health. Customers were instructed that they would be contacted by a Carestream Service Engineer to coordinate the deployment. Customers with questions were instructed to call 1-866 737 2487 or they may call the Carestream Customer Care Center at 1-800-328-2910, 8AM through 8pm Eastern Standard Time. For questions regarding this recall call 1-800-328-2910.

Device

  • 모델명 / 제조번호(시리얼번호)
    Model: Vue PACS client version 11.3.2.0 / 11.3.2.4 / 11.4 Catalog Number: 8656456
  • 의료기기 분류등급
  • 의료기기 등급
    2
  • 이식된 장치?
    No
  • 유통
    Worldwide Distribution - USA including AR, AZ, CA, CO, CT, FL, IA, IL, MA, MD, ME, MN, MO, NC, NH, NV, NY, OH, OK, PA, RI, TN, UT, VA WA, and WI and Internationally to Canada, Japan, and Kuwait.
  • 제품 설명
    Carestream Vue PACS; MX WEB SVR W/3 MX-RAD LIC<15K EXAMS || The CARESTREAM PACS is an image management system whose intended use is to provide completely scaleable local and wide area PACS solutions for hospital and related institutions/sites, which will archive, distribute, retrieve and display images and data from all hospital modalities and information systems.
  • Manufacturer

Manufacturer

  • 제조사 주소
    Carestream Health Inc., 150 Verona St, Rochester NY 14608-1733
  • 제조사 모회사 (2017)
  • Source
    USFDA