Device Recall ABL80 FLEX COOX analyzer 의 리콜

U.S. Food and Drug Administration에 따르면, 해당 리콜 는 United States 에서 Sendx Medical Inc 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

의료기기에 문제가 생겼을 경우 제조사가 이를 바로잡거나 시장에서 회수하는 조치를 말한다. 회수(Recall)는 의료기기에 결함이 있거나, 건강에 위협이 되거나, 또는 결함도 있고 건강에도 위협이 될 경우에 발생한다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Recall
  • 사례 ID
    63368
  • 사례 위험등급
    Class 2
  • 사례 연번
    Z-0195-2013
  • 사례 시작날짜
    2010-01-06
  • 사례 출판 날짜
    2012-11-05
  • 사례 상황
    Terminated
  • 사례 국가
  • 사례 종료 날짜
    2012-11-05
  • 사례 출처
    USFDA
  • 사례 출처 URL
  • 비고 / 경고
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • 데이터 추가 비고
    Electrode measurement, blood-gases (pco2, po2) and blood ph - Product Code CHL
  • 원인
    The recall was initiated because sendx medical inc. became aware of a software issue in the abl80 flex co-ox analyzer related to the reporting of the hemoglobin fractional parameters.
  • 조치
    SenDx Medical sent a recall letter to all their foreign customers on January 6, 2010, to informed them of the ABL80 FLEX CO-OX recall via the Radiometer Field Action Notification (FAN) system. The Field Action Notes informed the customers of the problem identified and the action to be taken. Customers were instructed to submit confirmation fax#1 to confirm that the customer letter has been distributed to all ABL80 CO-OX customers by January 31, 2010. Customers were instructed to submit confirmation fax #2 to confirm that all ABL80 CO-OX analyzers have been upgraded to version 1.35 by 6/30/10. In the U.S., the customer was provided with a software upgrade CD along with a letter advising them to the issues associated with the recall. Customers with questions were instructed to contact TechLine at (800) 736-0600 opt 2.

Device

  • 모델명 / 제조번호(시리얼번호)
    Serial Numbers: all ABL80 FLEX CO-OX analyzers with sofware versions 1.30, 1.31, 1.32, 1.33, and 1.34.
  • 의료기기 분류등급
  • 의료기기 등급
    2
  • 이식된 장치?
    No
  • 유통
    Worldwide Distribution-- US Distribution including the state of Ohio and the countries of Switzerland, Germany, France, Poland, Austria, Italy, Japan, Australia, Denmark, China, Sweden, Norway, Spain, United Kingdom, Netherlands, and Czech Republic.
  • 제품 설명
    ABL80 FLEX CO-OX analyzer, model #393-841 (all software versions prior to 1.35). || The ABL80 FLEX CO-OX is a portable, automated analyzer that measures pH, blood gases, electrolytes, glucose and oximetry in whole blood. The ABL80 FLEX CO-OX system is intended for use by trained technologists, nurses, physicians and therapists. It is intended for use in a laboratory environment, near patient or point of care setting
  • Manufacturer

Manufacturer

  • 제조사 주소
    Sendx Medical Inc, 1945 Palomar Oaks Way, Carlsbad CA 92011-1300
  • 제조사 모회사 (2017)
  • Source
    USFDA