Device Recall Access Free T4 Calibrator 의 리콜

U.S. Food and Drug Administration에 따르면, 해당 리콜 는 United States 에서 Beckman Coulter Inc. 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

의료기기에 문제가 생겼을 경우 제조사가 이를 바로잡거나 시장에서 회수하는 조치를 말한다. 회수(Recall)는 의료기기에 결함이 있거나, 건강에 위협이 되거나, 또는 결함도 있고 건강에도 위협이 될 경우에 발생한다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Recall
  • 사례 ID
    58163
  • 사례 위험등급
    Class 2
  • 사례 연번
    Z-1945-2011
  • 사례 시작날짜
    2010-11-11
  • 사례 출판 날짜
    2011-04-11
  • 사례 상황
    Terminated
  • 사례 국가
  • 사례 종료 날짜
    2012-07-11
  • 사례 출처
    USFDA
  • 사례 출처 URL
  • 비고 / 경고
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • 데이터 추가 비고
    Radioimmunoassay, free thyroxine - Product Code CEC
  • 원인
    The recall was initiated because the stability claim for access free t4 calibrator lot 014769 is not met. the affected t4 calibrator lot can produce quality control and patient results that are erroneously low (by greater than 2 standard deviations). an erroneously low patient result may lead to misdiagnosis and/or delayed treatment.
  • 조치
    The firm, Beckman Coulter, sent an "URGENT: PRODUCT CORRECTIVE ACTION" (PCA) letter dated November 29, 2010 to its customers. The letter described the product, problem and actions to be taken. The customers were instructed to do the following: ACTION/RESOLUTION: " Discontinue use of Access Free T4 calibrator lot 014769. " Review historical quality control performance and determine whether any reported patient results were obtained while using a faulty calibration. If results were affected, you will see a shift downward in control recovery that produces out-of-range low QC results. " If patient results were obtained with Access Free T4 calibrator lot number 014769, it is possible they are erroneously low. If any patient results were reported in the period between the time the erroneous calibration with the affected lot was performed and when a different calibrator lot was used, the laboratory should consider advising physicians to whom results were reported so they can evaluate whether diagnosis or treatment decisions should be revisited. " No further orders of Access Free T4 Calibrator lot number 014769 will be shipped. Alternate lots will be provided for current and future replenishment orders or requests. Consignees/customers were asked to share this information with laboratory staff and retain this notification as part of their laboratory Quality System documentation; and complete and return the enclosed RESPONSE FORM via fax to Beckman Coulter at 786-639-4000. For product replacement: " In the United States, please contact Client Services at 1-800-526-3821, option 1. " In Canada, please contact Customer Service at 1-800-463-7828. " Outside of the United States and Canada, contact local Beckman Coulter representative. Questions and answers regarding this issue were enclosed for consignee/customer reference. Additional questions, were directed to the Customer Support Center on the Beckman Coulter website at http://www.beckmancoulter.com/customer

Device

  • 모델명 / 제조번호(시리얼번호)
    Lot Numbers: 014769
  • 의료기기 분류등급
  • 의료기기 등급
    2
  • 이식된 장치?
    No
  • 유통
    Worldwide distribution: USA and countries including: Argentina, Belgium, Bosnia and Herzegovina, Canada, China, Colombia, Czech Republic, French Polynesia, Hong Kong, Ireland, Israel, Japan, Jordan, Kuwait, Malaysia, Mexico, Oman, Panama, Philippines, Russian Federation, South Africa, Switzerland, Taiwan, Thailand, Tunisia, United Kingdom, Venezuela, and Zambia.
  • 제품 설명
    Access Free T4 Calibrator, Part Number: 33885, Lot Numbers: 014769 || The Access Free T4 Calibrators are intended to calibrate the Access Free T4 assay for the quantitative determination of free thyroxine levels in human serum and plasma (heparin) using the Access Immunoassay Systems
  • Manufacturer

Manufacturer

  • 제조사 주소
    Beckman Coulter Inc., 200 S Kraemer Blvd, Brea CA 92821-6208
  • 제조사 모회사 (2017)
  • Source
    USFDA