Device Recall Baxter BM11A Blood Monitor Pump 의 리콜

U.S. Food and Drug Administration에 따르면, 해당 리콜 는 United States 에서 Baxter Healthcare Renal Div 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

의료기기에 문제가 생겼을 경우 제조사가 이를 바로잡거나 시장에서 회수하는 조치를 말한다. 회수(Recall)는 의료기기에 결함이 있거나, 건강에 위협이 되거나, 또는 결함도 있고 건강에도 위협이 될 경우에 발생한다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Recall
  • 사례 ID
    34245
  • 사례 위험등급
    Class 2
  • 사례 연번
    Z-0680-06
  • 사례 시작날짜
    2005-12-21
  • 사례 출판 날짜
    2006-03-29
  • 사례 상황
    Terminated
  • 사례 국가
  • 사례 종료 날짜
    2008-06-23
  • 사례 출처
    USFDA
  • 사례 출처 URL
  • 비고 / 경고
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • 데이터 추가 비고
    Dialyzer, High Permeability With Or Without Sealed Dialysate System - Product Code KDI
  • 원인
    Advisory to alert users to assure that the hemofilter of the blood line is in the horizontal position to avoid kinking of the bloodline tubing to avoid hemolysis, and to show the compatible blood tubing sets to be used with the bm11/bm11a blood monitor pump and bm25 system ultrafiltration hemodialysis system.
  • 조치
    Important Product Information letters dated 12/21/05 were sent to all BM-series instrument users, informing them of the potential for kinking of the tubing if the hemofilter is in the vertical position and the compatibility testing conducted on certain blood tubing sets for use with the BM-series instruments and Baxter''s recommendation that the following sets be used with the BM-series instruments: a) product code 5M3006M for use with the BM 11 and the BM 11a, when the BM 11a is used as a stand alone device; b) product code 5M3048 for use with the BM 11a when operated as part of the BM 25 System; and c) product code 5M3046 for use with the BM 14 part of the BM 25 System. Please note that the BM 14 cannot be used as a stand alone instrument. A fourth bloodline manufactured by Nextron and identified as a BM11 Low Volume Tubing (Baxter product code 5M3132 and Nextron code DHZ0006) was found to be unqualified for use for the BM series instruments. A recommended blood tubing sets and setup guide with diagrams was included with the letter. Both the letter and the setup guide contained the following warning: ''During machine set up, verify that the selected blood tubing set has been recommended for use with the Baxter bm11/bm11a Blood Monitor Pump and the Baxter bm25 System. Using non-recommended blood tubing sets, even if the blood tubing set fits and appears to function correctly, may have clinical consequences. These consequences may include blood tubing kinking, which may cause hemolysis. Clinical consequences of returning hemolyzed blood to a patient range from back pain and shortness of breath up to and including death.'' The users were also informed that the warning was being included in a new revision of the Operator''s Manual, and were requested to call Baxter''s Center for Service at 1-888-229-0001 to return any stocks of product code 5M3132 for credit. Any questions were directed to the Center for One Baxter at 1-800-422-9837.

Device

  • 모델명 / 제조번호(시리얼번호)
    all serial numbers
  • 의료기기 분류등급
  • 의료기기 등급
    2
  • 이식된 장치?
    No
  • 유통
    Nationwide including Puerto Rico, and internationally to Colombia, Hong Kong and China
  • 제품 설명
    Baxter BM11A Blood Monitor Pump hemodialysis machine; Baxter Healthcare Corporation, Deerfield, IL 60015; product code 5M3051, 5M3051R
  • Manufacturer

Manufacturer

  • 제조사 주소
    Baxter Healthcare Renal Div, 1620 Waukegan Rd Bldg R, Mc Gaw Park IL 60085-6730
  • Source
    USFDA