Device Recall Baxter SIGMA Spectrum Infusion Pump with Master Drug Library (Version 6 and Version 8) 의 리콜

U.S. Food and Drug Administration에 따르면, 해당 리콜 는 United States 에서 Baxter Healthcare Corporation 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

의료기기에 문제가 생겼을 경우 제조사가 이를 바로잡거나 시장에서 회수하는 조치를 말한다. 회수(Recall)는 의료기기에 결함이 있거나, 건강에 위협이 되거나, 또는 결함도 있고 건강에도 위협이 될 경우에 발생한다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Recall
  • 사례 ID
    80014
  • 사례 위험등급
    Class 2
  • 사례 연번
    Z-2113-2018
  • 사례 시작날짜
    2018-05-08
  • 사례 상황
    Open, Classified
  • 사례 국가
  • 사례 출처
    USFDA
  • 사례 출처 URL
  • 비고 / 경고
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • 데이터 추가 비고
    Pump, infusion - Product Code FRN
  • 원인
    The firm will be updating the instructions for use for the product. current ifus instruct users to lower the primary bag 20 inches below the secondary bag using a hanger when performing a secondary infusion. however, the firm supplies 12.5-inch hangers with the baxter disposable secondary sets.
  • 조치
    On May 8, 2018, Baxter issued a Medical Device Correction letter to its customers. Customers were advised of the issue and instructed to do the following: 1. The SIGMA SPECTRUM Infusion Pumps can continue to be safely used with the Baxter-provided 12.5-inch hanger. 2. The updated Instructions for Use will be made available by May 31, 2018. At that time, you may access the updated IFU online at the Baxter Global Technical E-Service Center at URL: https://service.baxter.com/tsportal/#/login. For additional questions and concerns about this issue please contact Baxter Healthcare Medina at 800-356-3454, Option 1, between the hours of 7:00 am and 7:00 pm Eastern Time. 3. If you purchased this product directly from Baxter, complete the enclosed Baxter customer reply form and return it to Baxter by faxing it to 224-270-5457 or scanning and e-mailing it to fca@baxter.com, even if you do not have any inventory. Returning the Baxter customer reply form promptly will prevent you from receiving repeat notices. 4. If you purchased this product form a distributor, please note that the Baxter customer reply form is not applicable. If a reply form is provided by your distributor or wholesaler, please return it to the supplier according to their instructions. 5. If you distribute this product to other facilities or departments within your institution, please forward a copy of this communication to them. 6. If you are a dealer, wholesaler, distributor/reseller, or original equipment manufacturer (OEM) that distributed any affected product to other facilities, please notify your customers of this Medical Device Correction in accordance with your customary procedures.

Device

  • 모델명 / 제조번호(시리얼번호)
    All serial numbers manufactured from7/1/2014 and forward, with release dates 7/1/2014 and forward.
  • 의료기기 분류등급
  • 의료기기 등급
    2
  • 이식된 장치?
    No
  • 유통
    Worldwide Distribution - US Nationwide and the country of Canada.
  • 제품 설명
    Baxter SIGMA Spectrum Infusion Pump with Master Drug Library (Version 8), infusion pump, 35700BAX2 || Product Usage: || The Baxter SIGMA Spectrum Infusion Pump with Master Drug Library is intended to be used for the controlled administration of fluids. These fluids may include pharmaceutical drugs, blood, blood products and mixture of required patient therapy. The intended routes of administration consist of the following clinically accepted routes: intravenous, arterial, subcutaneous, intrathecal, epidural or irrigation of fluid space. Spectrum Infusion Pump is intended to be used in conjunction with legally marketed intravenous administration sets and medications provided by the user. The Spectrum and Spectrum with Master Drug Library is suitable for many user facility applications such as but not limited to hospitals, outpatient care areas, homecare and ambulatory care services. Spectrum and Spectrum with Master Drug Library is intended to reduce operator interaction through automated programming thereby helping to reduce errors associated with complex device programming. Parameter programming requires trained healthcare professional confirmation of limits and drug therapy to the physicians directive.
  • Manufacturer

Manufacturer

  • 제조사 주소
    Baxter Healthcare Corporation, 711 Park Ave, Medina NY 14103-1036
  • 제조사 모회사 (2017)
  • Source
    USFDA