Device Recall Davol 의 리콜

U.S. Food and Drug Administration에 따르면, 해당 리콜 는 United States 에서 Davol, Inc., Sub. C. R. Bard, Inc. 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

의료기기에 문제가 생겼을 경우 제조사가 이를 바로잡거나 시장에서 회수하는 조치를 말한다. 회수(Recall)는 의료기기에 결함이 있거나, 건강에 위협이 되거나, 또는 결함도 있고 건강에도 위협이 될 경우에 발생한다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Recall
  • 사례 ID
    38634
  • 사례 위험등급
    Class 2
  • 사례 연번
    Z-1273-2007
  • 사례 시작날짜
    2007-07-16
  • 사례 출판 날짜
    2007-09-27
  • 사례 상황
    Completed
  • 사례 국가
  • 사례 출처
    USFDA
  • 사례 출처 URL
  • 비고 / 경고
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • 데이터 추가 비고
    Sterile Implant Cartridge - Product Code GDW
  • 원인
    Malformed constructs (straight shots) may form causing injury to user/patient.
  • 조치
    Davol issued recall letter notification on 7/16/07 via Federal Express. Sales of the disposable cartridges ceased July 31, 2007. Cartridges will not be requested to be returned to Davol. Customer requests to return cartridges will be managed on an account-by-account basis. A reminder Second Letter issued July 23,2007 as a follow-up to the letter of July 16, 2007. The second stage will be a series of three letters to customers following the cessation of disposable cartridge sales and to recall the re-usable handles. A Stock Status form will be provided to customers to inventory the product which they are returning. The Stock Status form will be used to document the handles being returned. In the event that the customer cannot locate one or more handles. All handles will be returned to Cranston and will be dispositioned. Account verification for the number of handles returned from the account will be performed. No verification testing will be performed on returned handles unless a formal complaint has been registered for a handle.

Device

  • 모델명 / 제조번호(시리얼번호)
    All lots
  • 의료기기 분류등급
  • 의료기기 등급
    2
  • 이식된 장치?
    Yes
  • 유통
    Worldwide-USA and Canada, Austria, Switzerland, Spain, Sweden, United Kingdom, Italy,Portugal, Greece,Holland, South Africa, Israel, Japan, Belgium, Denmark, Finland, France, and Germany
  • 제품 설명
    Davol Salute Short 18cm Sterile Implant Cartridge - 30 Q-ring;5/Box, Item Number: 0113061
  • Manufacturer

Manufacturer

  • 제조사 주소
    Davol, Inc., Sub. C. R. Bard, Inc., 100 Sockanossett Crossroad, Cranston RI 02920
  • Source
    USFDA