Device Recall GE Centricity PACS RA1000 Workstation 의 리콜

U.S. Food and Drug Administration에 따르면, 해당 리콜 는 United States 에서 GE Healthcare Integrated IT Solutions 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

의료기기에 문제가 생겼을 경우 제조사가 이를 바로잡거나 시장에서 회수하는 조치를 말한다. 회수(Recall)는 의료기기에 결함이 있거나, 건강에 위협이 되거나, 또는 결함도 있고 건강에도 위협이 될 경우에 발생한다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Recall
  • 사례 ID
    46306
  • 사례 위험등급
    Class 2
  • 사례 연번
    Z-1104-2008
  • 사례 시작날짜
    2007-12-28
  • 사례 출판 날짜
    2008-05-01
  • 사례 상황
    Terminated
  • 사례 국가
  • 사례 종료 날짜
    2010-05-17
  • 사례 출처
    USFDA
  • 사례 출처 URL
  • 비고 / 경고
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • 데이터 추가 비고
    patient image workstation - Product Code LLZ
  • 원인
    Report missing characters: four special characters, when entered into the exam notes, are not transferred to the preview panel or hard copy printout (greater than [>], less than [<], quotation mark ["], and apostrophe [']). this may not be evident to the end user, as the symbols only appear when the exam note window is open.
  • 조치
    GE Healthcare IITS sent Product Safety Notification letters dated 12/28/07 to all customers who have the GE Centricity PACS RA1000 Workstation software versions 2.1.X, or 3.0.X, informing them of the potential patient safety issue involving the exam notes window, which may be used to provide various patient information including lab results. To mitigate this problem, the users were instructed not to use the following four special characters (greater than sign >, less than sign <, double quotation mark " and apostrophe ') in the exam notes field in order to prevent any adverse patient events. For example, if a lab result was entered as GFR <60, it should be typed as GFR less than 60. The customers were requested to make sure that all necessary physicians and personnel at their location are made aware of the problem and the recommended actions provided. A software patch to permanently resolve the issue will be installed at no charge when it becomes available. Any questions were directed to the GE Customer Care Center at 800-437-1171.

Device

  • 모델명 / 제조번호(시리얼번호)
    GE Centricity PACS RA1000 Workstation Software versions 2.1.X. and 3.0.X.
  • 의료기기 분류등급
  • 의료기기 등급
    2
  • 이식된 장치?
    No
  • 유통
    Worldwide Distribution - USA, Australia, Belgium, Canada, Denmark, France, Germany, Hong Kong, Israel, Italy, Japan, Korea, Kuwait, Malaysia, New Zealand, Portugal, Saudi Arabia, Singapore, South Africa, Spain, Switzerland, Taiwan, Turkey, and United Kingdom.
  • 제품 설명
    GE Centricity PACS RA1000 Workstation; for diagnostic image analysis. GE Healthcare Integrated IT Solutions, Barrington, IL 60010
  • Manufacturer

Manufacturer

  • 제조사 주소
    GE Healthcare Integrated IT Solutions, 540 W Northwest Hwy, Barrington IL 60010-3051
  • Source
    USFDA