Device Recall GE Healthcarr Dash Port 2 Docking Station 의 리콜

U.S. Food and Drug Administration에 따르면, 해당 리콜 는 United States 에서 GE Healthcare, LLC 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

의료기기에 문제가 생겼을 경우 제조사가 이를 바로잡거나 시장에서 회수하는 조치를 말한다. 회수(Recall)는 의료기기에 결함이 있거나, 건강에 위협이 되거나, 또는 결함도 있고 건강에도 위협이 될 경우에 발생한다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Recall
  • 사례 ID
    63662
  • 사례 위험등급
    Class 2
  • 사례 연번
    Z-0814-2013
  • 사례 시작날짜
    2012-06-13
  • 사례 출판 날짜
    2013-02-14
  • 사례 상황
    Terminated
  • 사례 국가
  • 사례 종료 날짜
    2016-08-25
  • 사례 출처
    USFDA
  • 사례 출처 URL
  • 비고 / 경고
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • 데이터 추가 비고
    Monitor, physiological, patient(with arrhythmia detection or alarms) - Product Code MHX
  • 원인
    Ge has become aware of multiple issues affecting the dash 3000/4000/5000 and dashport 2 monitor. this report of correction encompasses the dashport 2 device, in which the dashport 2 stops communicating with the dash, resulting in loss of monitoring at the cic. the dashport 2 status leds in the back of the unit indicate unity network and dashport 2 to dash communication has stopped.
  • 조치
    GE Healthcare sent an Important Product Information Letter dated June 13, 2012 via FedEx to all affected customers. The letter identified the affected product, problem and actions to be taken. The letter indicated that the motherboard would be replaced, on request, should the customer continue to experience the issue. A second letter dated August 30th 2012 was issued informing consignees that the correction that was initially proposed did not fully correct the issues. Therefore, the motherboard replacement field action had been suspended. It further explained that the correction will be provided at no charge when it is available. For questions contact Technical Support at 1-800-558-7044.

Device

  • 모델명 / 제조번호(시리얼번호)
  • 의료기기 분류등급
  • 의료기기 등급
    2
  • 이식된 장치?
    No
  • 유통
    Worldwide Distribution and US (nationwide) including DC and the countries of ALGERIA, ARAB EMIRATES, AUSTRALIA, AUSTRIA, BANGLADESH, BELGIUM, BRAZIL, CANADA, CHINA, CYPRUS, CZECH REPUBLIC, DENMARK, EGYPT, FRANCE, GERMANY, INDIA, ISRAEL, ITA LY, JAPAN, JORDAN, KUWAIT, MOROCCO, NETHERLANDS, NEW ZEALAND, NORWAY, POLAND, PORTUGAL, RUSSIA, SAUDI ARABIA, SINGAPORE SLOVENIA, SOUTH KOREA, SPAIN SWEDEN SWITZERLAND, TAIWAN, TURKEY, UNITED KINGDOM.
  • 제품 설명
    GE Healthcare, Dash Port 2 Docking Station. || Product Usage: is a docking station (quick mount/dismount base) for a Dash patient monitor. The system is to monitor physiologic parameter data on adult, pediatric, and neonatal patients.
  • Manufacturer

Manufacturer

  • 제조사 주소
    GE Healthcare, LLC, 3000 N Grandview Blvd, Waukesha WI 53188-1615
  • 제조사 모회사 (2017)
  • Source
    USFDA