Device Recall Integra CUSA Excel Sterile Torque Wrench (23 kHz) 의 리콜

U.S. Food and Drug Administration에 따르면, 해당 리콜 는 United States 에서 Integra LifeSciences Corp. 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

의료기기에 문제가 생겼을 경우 제조사가 이를 바로잡거나 시장에서 회수하는 조치를 말한다. 회수(Recall)는 의료기기에 결함이 있거나, 건강에 위협이 되거나, 또는 결함도 있고 건강에도 위협이 될 경우에 발생한다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Recall
  • 사례 ID
    67902
  • 사례 위험등급
    Class 2
  • 사례 연번
    Z-1522-2014
  • 사례 시작날짜
    2014-03-10
  • 사례 출판 날짜
    2014-04-29
  • 사례 상황
    Terminated
  • 사례 국가
  • 사례 종료 날짜
    2015-02-13
  • 사례 출처
    USFDA
  • 사례 출처 URL
  • 비고 / 경고
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • 데이터 추가 비고
    Instrument, ultrasonic surgical - Product Code LFL
  • 원인
    Some 23 khz torque wrenches were incorrectly assembled and contained a 36 khz hex wrench insert instead of the 23 khz hex wrench insert.
  • 조치
    Integra sent an Urgent: Voluntary Medical Device Recall letter dated March 10, 2014, to all affected customers. The letter identified the product the problem and the action needed to be taken by the customer. The written notifications were delivered to US consignees by traceable courier service and non-US consignees by traceable email or facsimile. Integra is asking that you do the following: 1. Review your unused inventory of 23 kHz CUSA Sterile Torque Wrenches and determine if they are on the affected lot number list on the next page and if they are still in the box. 2. Complete the attached form. - If you do not have an affected lot number on the list (see page 2), YOU CAN CONTINUE TO USE THE WRENCHES. Check the box I do not have any affected products on the list - If you do have product(s) on the affected lot number list, AND THEY ARE STILL IN THE BOX, determine if the box also has a green dot sticker as in the photo below. If so, YOU CAN CONTINUE TO USE THE WRENCHES. Check the box I do not have any affected products on the list on page 2. 3. Complete the other information on the form if you do or do not have affected products, return the form by email or fax as indicated on the form. Keep a copy of the form for your records. When your form is received, if you have noted you have affected products Customer Service will contact you and provide an RMA number and directions to return the product, as well as input an order to replace the quantity you indicated on the form. Should you have any questions regarding these instructions, please contact Customer Service at 1-855-532-1723. We apologize for any inconvenience this may cause and thank you for your cooperation in this effort.

Device

  • 모델명 / 제조번호(시리얼번호)
    Product/Catalog Number C5601; Lot Numbers 1132424, 1132883, 1132884, 1133453, 1133454, 1133455, 1134067, 1134675, 1134873 and 1135014
  • 의료기기 분류등급
  • 의료기기 등급
    Unclassified
  • 이식된 장치?
    No
  • 유통
    Worldwide Distribution - USA (nationwide) including the countries of Australia, Canada, and Switzerland.
  • 제품 설명
    Integra CUSA Excel Disposable Wrench. Catalog Number C5601. The CUSA Excel+ Sterile 23 kHz Torque Wrench is an accessory used with the CUSA Excel+ System ultrasonic surgical instrument. The torque wrench is used to properly secure the CUSA tip to the CUSA handpiece in the sterile field.
  • Manufacturer

Manufacturer