U.S. Food and Drug Administration에 따르면, 해당 리콜 는 United States 에서 Bovie Medical Corporation 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

의료기기에 문제가 생겼을 경우 제조사가 이를 바로잡거나 시장에서 회수하는 조치를 말한다. 회수(Recall)는 의료기기에 결함이 있거나, 건강에 위협이 되거나, 또는 결함도 있고 건강에도 위협이 될 경우에 발생한다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Recall
  • 사례 ID
    79398
  • 사례 위험등급
    Class 2
  • 사례 연번
    Z-1157-2018
  • 사례 시작날짜
    2018-02-08
  • 사례 상황
    Open, Classified
  • 사례 국가
  • 사례 출처
    USFDA
  • 사례 출처 URL
  • 비고 / 경고
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • 데이터 추가 비고
    Electrosurgical, cutting & coagulation & accessories - Product Code GEI
  • 원인
    Bovie medical is issuing a correction to address incomplete insertion of the j-plasma(r) handpiece cable plug into the generator receptacle resulting in an incomplete helium seal. the potential exists for patient fluid backflow into the handpiece and the generator receptacle leading to risk of cross-contamination if the generator is reused.
  • 조치
    The firm initiated their recall on 02/08/2108 by email to distributors, and letter to the remaining consignees. Distributors were directed as follows: "We ask that you immediately: 1. Quarantine your inventory of the J-Plasma Handpieces o Provide us with a list of catalog numbers and quatities that you have on your possession using the attached Inventory List template. o Email the information to me at Rubiela.Maldonado@boviemed.com Note: as soon as we receive the information from you we will ship the box labels and insert stuffer notices for the stock that you have on your possession. o After receiving these labels, please follow the attached instructions on how to add each of the insert stuffer notice and the outer box label to each of the boxes that you have on your possession. o Document the number of labels/stuffers added to each of the products on the Inventory List provided, sign and date to confirm this was performed. o Return the signed document to me via email at Rubiela.maldonado@boviemed.com. 2. Inform your customers about the correction: o Identify and contact your customers that have received the product affected by this correction. o Provide them with a copy of the Urgent Medical Device Correction Template attached to this letter. o Track and document the customer responses to ensure 100% effectiveness. o Provide us a summary of the effectiveness of this correction (number of customers impacted and number of responses received)." The remaining consignees (users of the device) were instructed as follows: "ACTIONS: At the end of each procedure, inspect the handpiece cable plug and generator receptacle for the presence of fluids. If fluids are present, immediately discontinue use of the generator. In addition to following the J-Plasma¿ handpiece Instructions for Use, immediately begin to follow the supplemental instructions provided below to ensure that the J-Plasma¿ handpiece cable plug is properly and co