Device Recall Liko Standard Slingbar 450. 의 리콜

U.S. Food and Drug Administration에 따르면, 해당 리콜 는 United States 에서 Hill-Rom, Inc. 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

의료기기에 문제가 생겼을 경우 제조사가 이를 바로잡거나 시장에서 회수하는 조치를 말한다. 회수(Recall)는 의료기기에 결함이 있거나, 건강에 위협이 되거나, 또는 결함도 있고 건강에도 위협이 될 경우에 발생한다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Recall
  • 사례 ID
    62413
  • 사례 위험등급
    Class 2
  • 사례 연번
    Z-0622-2013
  • 사례 시작날짜
    2012-12-06
  • 사례 출판 날짜
    2012-12-31
  • 사례 상황
    Terminated
  • 사례 국가
  • 사례 종료 날짜
    2014-11-06
  • 사례 출처
    USFDA
  • 사례 출처 URL
  • 비고 / 경고
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • 데이터 추가 비고
    Lift, patient, non-ac-powered - Product Code FSA
  • 원인
    Liko/hill-rom has received reports from facilities which indicate that serious injuries have been received related to the standard sling bar 450. there have been 6 complaints of injury related to the product over the past 32 years (6 out of 838,687,856 estimated patient uses). one of the injuries was associated with a patient during use, four injuries occurred when the slingbar was not in use wher.
  • 조치
    Hill-rom sent an URGENT MEDICAL DEVICE RECALL notification letter dated December 6, 2012, to all affected customers. The letter identified the product the problem and the action needed to be taken by the customer.. Customers were requested to please read, fill in completely, and return the Response Form to Hill-Rom immediately. This information will be compiled and reported to the applicable regulatory governing bodies. If we do not receive your response we will be required to contact you asking for your response. Continue to follow safe lifting practices, and do not allow unauthorized persons, especially children, to play around or operate the lift. If you have any questions concerning this Customer Safety Notification, please contact Hill-Rom Technical Support at 800-445-3720.

Device

  • 모델명 / 제조번호(시리얼번호)
    The Liko Standard Slingbar 450 accessory has been supplied under multiple product numbers and combined with the sale of mobile lifts. The Standard Slingbar 450 is not serialized and has been distributed between January 1980 and the present. Here are the different Product Numbers in which the Slingbar has been shipped under: Standard Slingbar 450: 20090029, 20190024, 20190041, 31190015, 31290017, 31290043, 3156001, 3156003, 3156007, 3156014, 3156016, 31590043, and 5019013.  Packaged with Golvo up to April of 2005: 2000001, 2000003, 2000005, 2000006, 2000007, 2000008, 2000009, 2000009CH, 2000009D, 2000009DK, 2000009EU, 2000009F, 2000009FIN, 2000009J, 2000009N, 2000009NL, 2000009UK, 2000009U5, 2000010, 20000100, 20000100K, 2000010EU, 2000010F, 2000010FIN, 2000010H, 2000010J, 2000010N, 2000010NL, 2000010UK, 200001OU5, 2000050, 2000051, 2000061, IN8000, and IN8061.  Packaged with Viking up to December of 2004: 2040003, 2040003L, 2040004, 2040005, 2040006, 2040007, 2040013, 2040014, 2040015, 2040033, 2040034, and 2040035.  Packaged with LikoLight up to December of 2004: 2030001 and 2030001H.  Packaged with Uno lifts up to present: 2010001, 2010002, 2010003, 2010003D, 2010003EU, 2010003F, 2010003H, 2010003N, 2010003UK, 2010003US, 2010004, 2010004D, 2010004EU, 2010004F, 2010004H, 2010004N, 2010004UK, 2010004US, 2010005, 20100050, 2010005EU, 2010005F, 2010005N, 2010005UK, 2010005U5, 2010011, 2010012, 5E2010004, and 5E2010011.  Packaged with Caroli lifts up to present: 5011001.
  • 의료기기 분류등급
  • 의료기기 등급
    1
  • 이식된 장치?
    No
  • 유통
    Worldwide Distribution -- US (nationwide) including the states of AR, AZ, CA, CO, FL, GA, HI, IA, IL, IN, KS, KY, MA, ME, MI, MN, MO, MS, NC, NE, NJ, NM, NV, NY, OK, OR, PA, TN, TX, UT, WA, WV, and WY., and the country Canada, We have not yet defined our European or International facilities at this time.
  • 제품 설명
    Liko Standard Slingbar 450. || The Standard Slingbar 450 is a versatile sling bar which can be used for most lifting situations. It can be used with different Liko ceiling and mobile lifts.
  • Manufacturer

Manufacturer

  • 제조사 주소
    Hill-Rom, Inc., 1069 State Route 46 East, Batesville IN 47006-7520
  • 제조사 모회사 (2017)
  • Source
    USFDA