Device Recall Malibu Polyaxial Screw 의 리콜

U.S. Food and Drug Administration에 따르면, 해당 리콜 는 United States 에서 SeaSpine, Inc 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

의료기기에 문제가 생겼을 경우 제조사가 이를 바로잡거나 시장에서 회수하는 조치를 말한다. 회수(Recall)는 의료기기에 결함이 있거나, 건강에 위협이 되거나, 또는 결함도 있고 건강에도 위협이 될 경우에 발생한다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Recall
  • 사례 ID
    52115
  • 사례 위험등급
    Class 2
  • 사례 연번
    Z-1923-2009
  • 사례 시작날짜
    2009-03-04
  • 사례 출판 날짜
    2009-09-03
  • 사례 상황
    Terminated
  • 사례 국가
  • 사례 종료 날짜
    2011-04-28
  • 사례 출처
    USFDA
  • 사례 출처 URL
  • 비고 / 경고
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • 데이터 추가 비고
    Spinal Interlaminal Fixation Appliance - Product Code KWP
  • 원인
    Seaspine has received reports relating to rust on the internal washer contained within the titanium seat assembly of certain malibu polyaxial and malibu reduction screws.
  • 조치
    In an Urgent Voluntary Product Recall Notification letter dated March 5th, 2009, SeaSpine informed consignees about the reason for recall and asked them to immediately check the products in their possession and hospital inventories to determine if they have any of the affected product. Alternatively, there were told if they would prefer to return to SeaSpine all Malibu Screw inventory that is in their possession, SeaSpine will sort out the affected product upon receipt and will replace their inventory with Malibu Screws that conform to all SeaSpine specifications. The part number and lot are laser marked on the outside of the seat assembly of each screw. SeaSpine asked their consignees to return affected product to them immediately. Attached was a verification form, that they were told to complete and return even if they did not have any product to return. Furthermore their local Sales Manager could assist them in completing the form. They were also encouraged to contact their Sales Manager or Steve Rybka at (760) 727-8399 x202 if they had any questions regarding the recall, any of their products, or would like assistance with the recall.

Device

  • 모델명 / 제조번호(시리얼번호)
    Lot Number: A1762B
  • 의료기기 분류등급
  • 의료기기 등급
    2
  • 이식된 장치?
    Yes
  • 유통
    Worldwide Distribution -- USA, including states of AL, AZ, CA, CO, FL, GA, IN, MD, MI, MO, MS, NM, OK, TN, TX, VA, and WI and country of Greece.
  • 제품 설명
    Malibu Polyaxial Screw, 7.5 x 35mm Part Number 12-7535 || Malibu Spinal System when used as a Pedicle Screw Spinal System or Spondylolisthesis Spinal Fixation Device System is to provide immobilization in the treatment of acute and chronic instabilities or deformities of the thoracic, lumbar, and sacral spine.
  • Manufacturer

Manufacturer

  • 제조사 주소
    SeaSpine, Inc, 2302 La Mirada Dr, Vista CA 92081-7862
  • Source
    USFDA