Device Recall PremierEdge MICROSURGICAL KNIFE 2.85mm Clear Cornea Knife Parallel Sides 의 리콜

U.S. Food and Drug Administration에 따르면, 해당 리콜 는 United States 에서 Oasis Medical Inc 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

의료기기에 문제가 생겼을 경우 제조사가 이를 바로잡거나 시장에서 회수하는 조치를 말한다. 회수(Recall)는 의료기기에 결함이 있거나, 건강에 위협이 되거나, 또는 결함도 있고 건강에도 위협이 될 경우에 발생한다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Recall
  • 사례 ID
    45870
  • 사례 위험등급
    Class 2
  • 사례 연번
    Z-0498-2008
  • 사례 시작날짜
    2007-07-18
  • 사례 출판 날짜
    2008-01-12
  • 사례 상황
    Terminated
  • 사례 국가
  • 사례 종료 날짜
    2009-09-25
  • 사례 출처
    USFDA
  • 사례 출처 URL
  • 비고 / 경고
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • 데이터 추가 비고
    Ophthalmic Knife - Product Code HNN
  • 원인
    Sterility (package integrity) compromised: the device is puncturing the packing during handling. once the packaging is damaged, the product is no longer sterile as labeled. this is an expansion of a previous recall.
  • 조치
    A recall notification, Urgent Medical Device Recall Expansion Letter, dated 7.18.2007, was sent to customers advising the letter is to inform them of a voluntary product recall expansion involving the OASIS Medical Premier Edge Knives. A product label for ease in identifying the product is included. The letter further advises this voluntary recall has been expanded due to the product puncturing the packing during rough handling. Once the packaging is damaged, the product is no longer sterile as labeled. The letter instructs customers to immediately examine their inventory and quarantine product subject to recall. Once the product has been identified, product is to be returned by FedEx to OASIS Medical. The letter further instructs that if the customer has further distributed this product, to identify their customers and notify them at once of this product recall. This recall should be carried out to the user level.

Device

  • 모델명 / 제조번호(시리얼번호)
    Lot No: DK0307O and DK0407K
  • 의료기기 분류등급
  • 의료기기 등급
    1
  • 이식된 장치?
    No
  • 유통
    Worldwide: USA, Kuwait, Lebanon, Lithuania, Mexico, Netherlands, Norway, South Africa, Saudi Arabia, Slovakia, Spain, Sweden, Switzwerland, Turkey, United Kingdom, Ecuador, Finland, France, Germany, Greece, Italy, Denmark, Columbia, Chile, Brazil, Belgium, and Australia
  • 제품 설명
    PremierEdge MICROSURGICAL KNIFE, 2.85mm Clear Cornea Knife - Parallel Sides, Item Code/REF: PE 3228, OASIS Glendora, CA 91741
  • Manufacturer

Manufacturer

  • 제조사 주소
    Oasis Medical Inc, 514 S Vermont Ave Bldg 510-528, Glendora CA 91741-6205
  • 제조사 모회사 (2017)
  • Source
    USFDA