Device Recall Pressure Injectable Multi 의 리콜

U.S. Food and Drug Administration에 따르면, 해당 리콜 는 United States 에서 Arrow International Inc 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

의료기기에 문제가 생겼을 경우 제조사가 이를 바로잡거나 시장에서 회수하는 조치를 말한다. 회수(Recall)는 의료기기에 결함이 있거나, 건강에 위협이 되거나, 또는 결함도 있고 건강에도 위협이 될 경우에 발생한다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Recall
  • 사례 ID
    79339
  • 사례 위험등급
    Class 2
  • 사례 연번
    Z-0994-2018
  • 사례 시작날짜
    2017-11-27
  • 사례 상황
    Open, Classified
  • 사례 국가
  • 사례 출처
    USFDA
  • 사례 출처 URL
  • 비고 / 경고
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • 데이터 추가 비고
    Catheter,intravascular,therapeutic,short-term less than 30 days - Product Code FOZ
  • 원인
    Some of the products listed in the recall may be missing a sticker that contains the lot number, expiration date, and unique device identification (udi) information.
  • 조치
    On November 29, 2017 an Urgent Medical Device Correction notice was issued to customers stating the following: Our records indicate that you have received products that are subject to this action. We are now notifying our distributors to take the following actions: 1. Immediately discontinue distribution and quarantine any products with the product codes and lot numbers listed above. 2. Inspect affected products within your control to identify whether they have the sticker with the lot number, expiration date, and UDI information. Products missing this sticker should be returned to Arrow International so they are not distributed to health care providers in error. Products which are properly labeled should not be returned. 3. Using the provided Customer Letter and Acknowledgement Form templates, communicate this correction to any of your customers who have received products included within the scope of the correction. Customers should return mislabeled products. Products that are properly labeled should not be returned. 4. If any of your customers have mislabeled products to return, have them return the affected products to you, together with a completed Acknowledgement Form, for consolidation and return to Arrow International. In the event that an alternative approach is needed, contact Customer Service for more information at 1-866-246-6990. 5. To return products to Arrow International, complete the enclosed Acknowledgement Form and fax it to 1-855-419-8507, Attn: Customer Service or email it to recalls@teleflex.com. This will allow us to document the amount of product you have on hand for return. A customer service representative will contact you with a Return Goods Authorization (RGA) Number and will provide instructions for the return of product to Arrow International. 6. If you and your customers have no affected stock or if the products in your stock are properly labeled, please complete the enclosed Acknowledgment Form and fax it to 1-855-419

Device

  • 모델명 / 제조번호(시리얼번호)
    ASK-12703-PRJ 13F17B0279 13F17D0112 ASK-15703-PRJ  13F17B0265
  • 의료기기 분류등급
  • 의료기기 등급
    2
  • 이식된 장치?
    No
  • 유통
    US in the states of OH, FL, SC, TX, KY, NJ, MI
  • 제품 설명
    Multi-Lumen Central Venous Catheterization Kit with Blue FlexTip(R) Catheter and Sharps Safety Features || Product Usage: || The Arrow¿ CVC is indicated to provide short-term (< 30 days) central venous access for treatment of diseases or conditions requiring central venous access including, but not limited to:  multiple infusions of fluids, medications, or chemotherapy  infusion of fluids that are hypertonic, hyperosmolar, or have  divergent pH values  frequent blood sampling or blood/blood component infusions  infusion of incompatible medications  central venous pressure monitoring  lack of usable peripheral IV sites  replacement of multiple peripheral sites for IV access  injection of contrast media  When used for pressure injection of contrast media, do not exceed the maximum indicated flow rate for each catheter lumen. The maximum pressure of power injector equipment used with pressure injectable CVC may not exceed 400 PSI.
  • Manufacturer

Manufacturer

  • 제조사 주소
    Arrow International Inc, 2400 Bernville Rd, Reading PA 19605-9607
  • 제조사 모회사 (2017)
  • Source
    USFDA