Device Recall Rolko Adjustable Strap and Handle 의 리콜

U.S. Food and Drug Administration에 따르면, 해당 리콜 는 United States 에서 Arjo, Inc. dba ArjoHuntleigh 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

의료기기에 문제가 생겼을 경우 제조사가 이를 바로잡거나 시장에서 회수하는 조치를 말한다. 회수(Recall)는 의료기기에 결함이 있거나, 건강에 위협이 되거나, 또는 결함도 있고 건강에도 위협이 될 경우에 발생한다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Recall
  • 사례 ID
    57953
  • 사례 위험등급
    Class 2
  • 사례 연번
    Z-1933-2011
  • 사례 시작날짜
    2011-02-24
  • 사례 출판 날짜
    2011-04-11
  • 사례 상황
    Terminated
  • 사례 국가
  • 사례 종료 날짜
    2011-06-14
  • 사례 출처
    USFDA
  • 사례 출처 URL
  • 비고 / 경고
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • 데이터 추가 비고
    Bed, hydraulic, adjustable hospital - Product Code FNK
  • 원인
    Part of the housing of the strap retracting mechanism built into the handle may break while the patient is using the handle and strap.
  • 조치
    ArjoHuntleigh sent an Urgent Field Safety Notice to all affected end users via UPS Ground on February 24, 2011. The notice informed the accounts of the potential for the strap retracting mechanism to break during use. The accounts were requested to check their inventory for the presence of adjustable straps and handles procured from ArjoHuntleigh, note if they have a red button on the retractor housing and the affected production dates as explained in the photographs in Figures 1 and 2 in the letter. Any straps and handles found as identified in Figures 1 and 2 should be removed from use and returned to ArjoHuntleigh. Any straps and handles with a yellow button design as shown in Figure 3 are not affected and can continue being used. The accounts were requested to complete and fax or mail the enclosed Customer Response Form to Arjo at 630-576-5012, indicating the number of strap and handles checked and how many were removed from use. Questions were directed to the ArjoHuntleigh Regulatory Department at 1-630-785-4885.

Device

  • 모델명 / 제조번호(시리얼번호)
    type TGN-R100GR strap and handle, produced between January 2007 and January 2009, which can be identified by the red button on the retractor housing and the traceability mark on the side of the housing. The traceability mark has the last two digits of the year in the inner circle with an arrow pointing to the month on the outer circle. Any strap and handle with a yellow button on the housing is not affected by the recall. The strap and handle was sold under part numbers CM-ACC09-1 and ENT-ACC01 by ArjoHuntleigh.
  • 의료기기 분류등급
  • 의료기기 등급
    1
  • 이식된 장치?
    No
  • 유통
    Nationwide Distribution including California, Georgia, Hawaii, Michigan, South Carolina and Texas
  • 제품 설명
    Rolko Adjustable (retractable) Strap and Handle, type TGN-R100GR; a component of a Lifting Pole, an accessory to long term care hospital beds such as ArjoHuntleigh's Minuet 2 Community bed and Enterprise series hospital beds; Distributed by ArjoHuntleigh, a Branch of Arjo Limited Med AB, Wednesbury, United Kingdom || Lifting poles are accessories intended to assist patients in positioning themselves on a hospital bed and the lifting pole is used in conjunction with a strap and handle. The strap and handle hangs from the lifting pole and the patient grasps the handle to pull upon the strap when repositioning themselves
  • Manufacturer

Manufacturer

  • 제조사 주소
    Arjo, Inc. dba ArjoHuntleigh, 2349 W Lake St, Addison IL 60101-6183
  • 제조사 모회사 (2017)
  • Source
    USFDA