Device Recall VP 2000 Processor Heated Reagent Basins 의 리콜

U.S. Food and Drug Administration에 따르면, 해당 리콜 는 United States 에서 Abbott Molecular 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

의료기기에 문제가 생겼을 경우 제조사가 이를 바로잡거나 시장에서 회수하는 조치를 말한다. 회수(Recall)는 의료기기에 결함이 있거나, 건강에 위협이 되거나, 또는 결함도 있고 건강에도 위협이 될 경우에 발생한다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Recall
  • 사례 ID
    56284
  • 사례 위험등급
    Class 2
  • 사례 연번
    Z-2313-2010
  • 사례 시작날짜
    2010-07-20
  • 사례 출판 날짜
    2010-08-31
  • 사례 상황
    Terminated
  • 사례 국가
  • 사례 종료 날짜
    2012-04-19
  • 사례 출처
    USFDA
  • 사례 출처 URL
  • 비고 / 경고
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • 데이터 추가 비고
    Automated Slide Stainer - Product Code KPA
  • 원인
    The vp2000 processor heated reagent basins crack along the bottom seam, have non-uniform coating of interior corners, may be warped, and some may have incorrect dimensions.
  • 조치
    Abbott sent Urgent Product Recall letters dated 7/20/10 to the VP 2000 Processor customers on same date via FedEx, informing them that the heated reagent basins could crack along the bottom seam, have non-uniform coating of interior corners, warping of the aluminum housing or incorrect dimensions. These deficiencies could result in leakage or the inability to place the basins into the VP 2000 Processor, resulting in possible exposure to chemical reagents, a slippery floor hazard, and/or delay or failure to start a protocol run. An Abbott Molecular customer service representative will call them to coordinate replacement of all of their heated reagent basins before 10/31/10. Customers were to complete and return the Customer Reply form provided. Any questions were directed to their local Abbott Molecular Representative. *** A second recall letter was sent to all customers on 12/21/10 explaining that the VP 2000 heated reagent basins previously inspected and determined to be acceptable could develop a leak, and that they would be contacted by an Abbott Molecular Customer Service Representative or Field Service representative in early 2011 to coordinate replacement of all of their VP 2000 heated reagent basins. ***

Device

  • 모델명 / 제조번호(시리얼번호)
    All basins distributed since September 2008.
  • 의료기기 분류등급
  • 의료기기 등급
    1
  • 이식된 장치?
    No
  • 유통
    Worldwide Distribution -- Australia, Belgium, France, Germany, India, Italy, Japan, Pakistan, Poland, Russia, Singapore, South Korea, Switzerland, Taiwan, Thailand, United Kingdom, Uruguay, and the United States.
  • 제품 설명
    VP 2000 Processor Heated Reagent Basins; automated slide stainer; Abbott Molecular Inc., Des Plaines, IL 60018; The basins are sold under the the following part numbers: || a) list 02J11-013, part number 30-144152 (replacement basins); || b) list 02J11-060, part number 30-144100 (as a component of the 100 volt VP 2000 Processor); || c) list 02J11-001, part number 30-144101 (as a component of the 117 volt VP 2000 Processor); || d) list 02J11-004, part number 30-144102 (as a component of the 230 volt VP 2000 Processor); || Designed to automate and standardize FISH slide specimen processing and routine slide staining for the laboratory.
  • Manufacturer

Manufacturer

  • 제조사 주소
    Abbott Molecular, 1300 E Touhy Ave, Des Plaines IL 60018-3315
  • Source
    USFDA