Integrated Data Management System Version 7.1, 7.2 and 7.3; 의 리콜

U.S. Food and Drug Administration에 따르면, 해당 리콜 는 United States 에서 International Technidyne Corporation 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

의료기기에 문제가 생겼을 경우 제조사가 이를 바로잡거나 시장에서 회수하는 조치를 말한다. 회수(Recall)는 의료기기에 결함이 있거나, 건강에 위협이 되거나, 또는 결함도 있고 건강에도 위협이 될 경우에 발생한다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Recall
  • 사례 ID
    55427
  • 사례 위험등급
    Class 3
  • 사례 연번
    Z-2438-2010
  • 사례 시작날짜
    2010-04-09
  • 사례 출판 날짜
    2010-09-20
  • 사례 상황
    Terminated
  • 사례 국가
  • 사례 종료 날짜
    2011-05-25
  • 사례 출처
    USFDA
  • 사례 출처 URL
  • 비고 / 경고
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • 데이터 추가 비고
    Calculator/data processing module, for clinical use - Product Code JQP
  • 원인
    A tabulation error in the integrated data management systems (idms) data management software that results in incorrect electronic quality control (eqc) summary reports: the operator and the device performance summary reports. the idms software is not used for the clinical management of individual patients.
  • 조치
    ITC sent an URGENT MEDICAL DEVICE CORRECTION letter dated March 10, 2010 to Distributors and First Consignee End Users identifying the affected product and affected summary reports, the reason for recall, and the actions to be taken by the distributors and customers. New Errata Instructions were enclosed with each letter and are to be put in the idms user guide for reference. The new instructions are to be followed when running reports for the ESV or TVT tests run by the Hemochron Response. The enclosed Customer Account Tracking Form is to be completed and returned to ITC indicating that the letter has been received and appropriate questions answered as to the use of the software system. Distributors are asked to check inventory for recalled product. If affected product is found, shipment should be stopped and placed on hold. Distributors should notify customers of the correction and provide them with a copy of the correction letter and updated instructions. This should be done by traceable mail. Distributors should return the account tracking form and return affected software disks for replacement. Questions should be directed to ITC Technical Support at 800-631-5945.

Device

  • 모델명 / 제조번호(시리얼번호)
    Product code 464100, Version numbers 7.1.0, 7.2.0 and 7.3.0.
  • 의료기기 분류등급
  • 의료기기 등급
    1
  • 이식된 장치?
    No
  • 유통
    Worldwide distribution: USA including the states of AL, AZ, CA, FL, GA, IL, KS, LA, MD, MI, NC, ND, NJ, NM, NY, OH, PA, TN , TX, UT, VA, WA, and WI, and the countries of Italy, Turkey, Canada, France, Belgium, Germany, UAE, and New Zealand.
  • 제품 설명
    Integrated Data Management System - Version 7.1, 7.2 and 7.3; || ITC Corporation, 8 Olsen Place South, Piscataway, NJ 08854