Leksell Gamma Knife C 의 리콜

U.S. Food and Drug Administration에 따르면, 해당 리콜 는 United States 에서 Elekta, Inc. 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

의료기기에 문제가 생겼을 경우 제조사가 이를 바로잡거나 시장에서 회수하는 조치를 말한다. 회수(Recall)는 의료기기에 결함이 있거나, 건강에 위협이 되거나, 또는 결함도 있고 건강에도 위협이 될 경우에 발생한다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Recall
  • 사례 ID
    55148
  • 사례 위험등급
    Class 2
  • 사례 연번
    Z-1429-2010
  • 사례 시작날짜
    2006-08-01
  • 사례 출판 날짜
    2010-04-22
  • 사례 상황
    Terminated
  • 사례 국가
  • 사례 종료 날짜
    2010-12-14
  • 사례 출처
    USFDA
  • 사례 출처 URL
  • 비고 / 경고
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • 데이터 추가 비고
    Radionuclide radiation therapy system - Product Code IWB
  • 원인
    Due to a material change in a critical component of the linear actuators the quality of said part was found to be inadequate.
  • 조치
    Phase 1 - Technical Notes Leksell Gamma Knife C version 1.2 (dated August 2006) "Potential Problem with Error Handling" was sent to all users. Phase 2 - Mandatory Field Action 0000748, "Helmet Changer Actuator, MTB and MCU SW Upgrade Kit was released December 3, 2007. This Field Change Order includes two mod kits and a software upgrade to provide a permanent solution to the issues. Phase 3 - Technical Note 200 068, "Safety issue with helmet host actuator", released on May 15, 2008. This Technical Note includes a warning to customers of a potential quality problem with the helmet hoist actuator that is installed in the Leksell Gamma Knife. Phase 4 - Mandatory Field Action 200 067, "Investigation and Correction of Helmet Changer Actuators", released on May 15, 2008. This FCO includes a list of user machines which must be monitored for quality issues and provides a solution for replacement of parts should a deficiency be detected. Phase 5 - Mandatory Field Action 200 075, "Helmet Changer Actuator, MTB and MCU SW upgrade, release two", released on September 16, 2008. This FCO applies to machines within specific serial number ranges. Due to a material change in FCO-0000748 and baselines (conducted without notice by the manufacturer) the quality of said part was found to be inadequate. After reversing the material change, FCO 200 075 is released to update the installed base with the new type of actuator and to finish the remaining sites never or partially updated by the now superseded FCO-0000748. For further information, contact Elekta R&D; Jonas Hallstensson on phone no. +46 709 843 553 or via e-mail jonas.hallstensson AT elekta.com.

Device

  • 모델명 / 제조번호(시리얼번호)
    4148, 4207, 4214, 4300, 4302, 4303, 4306, 4307, 4308, 4309, 4313, 4314, 4315, 4318, 4319, 4321, 4322, 4326, 4327, 4328, 4329, 4332, 4333, 4334, 4337, 4338, 4339, 4340, 4341, 4342, 4343, 4344, 4346, 4351, 4352, 4353, 4354, 4357, 4363, 4365, 4366, 5000, 5003, 5006, 5009, 5010, 5018, 5019, 5022, 5023, 5026
  • 의료기기 분류등급
  • 의료기기 등급
    2
  • 이식된 장치?
    No
  • 유통
    AL, CA, CO, CT, FL, GA, IL, MD, MA, MI, MN, MO, NE, NY, NC, OH, OK, OR, PA, TN, TX, VA, WA
  • 제품 설명
    Leksell Gamma Knife C
  • Manufacturer

Manufacturer

  • 제조사 주소
    Elekta, Inc., 4775 Peachtree Industrial Blvd, Bldg 300, #300, Norcross GA 30092-3011
  • 제조사 모회사 (2017)
  • Source
    USFDA