Synthes Spiral Blade Component of the Synthes Modular Blade Plate System 의 리콜

U.S. Food and Drug Administration에 따르면, 해당 리콜 는 United States 에서 Synthes USA (HQ), Inc. 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

의료기기에 문제가 생겼을 경우 제조사가 이를 바로잡거나 시장에서 회수하는 조치를 말한다. 회수(Recall)는 의료기기에 결함이 있거나, 건강에 위협이 되거나, 또는 결함도 있고 건강에도 위협이 될 경우에 발생한다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Recall
  • 사례 ID
    57318
  • 사례 위험등급
    Class 2
  • 사례 연번
    Z-1284-2011
  • 사례 시작날짜
    2010-10-27
  • 사례 출판 날짜
    2011-02-16
  • 사례 상황
    Terminated
  • 사례 국가
  • 사례 종료 날짜
    2015-04-16
  • 사례 출처
    USFDA
  • 사례 출처 URL
  • 비고 / 경고
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • 데이터 추가 비고
    Appliance, fixation, nail/blade/plate combination - Product Code KTW
  • 원인
    Potential for out of specification star grind teeth.
  • 조치
    Synthes initiated their recall on October 18, 2010, notifying affected hospital accounts via consultant communication. Affected Synthes Trauma Sales Consultants were notified via email (receipt requested). A copy of the Urgent Medical Device Recall letter dated October 20, 2010, was mailed via UPS second day air on October 20, 2010. The letter identified the product, the problem, and the action to be taken by the customer. Customers were instructed to identify any affected devices and call Synthes at 1-800-479-6329 to obtain a Return Authorization Number. A replacement order would be taken at that time. Customers were also instructed to complete the Verification Section at the end of the letter by checking the appropriate box indicating the affected product had been located or indicating in the appropriate box that no affected product was located. Also, customers were to indicate the number of devices found and note the Return Authorization Number. Return the Verification Form with the recalled product to: Credit/Returns, Synthes, 1101 Synthes Avenue, Monument, CO 80132. For questions regarding this recall call 1-800-620-7025, x 6883.

Device

  • 모델명 / 제조번호(시리얼번호)
    All lots of Part Number: 02.122.580S, 80mm Spiral Blade, 14mm, Right-Sterile
  • 의료기기 분류등급
  • 의료기기 등급
    2
  • 이식된 장치?
    Yes
  • 유통
    Nationwide Distribution including AL, CA, GA, IA, IL, IN, MA, MI, MS, NC, NJ, NV, OH, PA, SC, SD, TN, and WV.
  • 제품 설명
    02.122.580S, 80mm Spiral Blade, 14mm, || Right-Sterile - Synthes Spiral Blade Component of the Synthes Modular Blade Plate SystemFor fixation of fractures and osteotomies of the proximal and distal femur in adolescents and adults.
  • Manufacturer

Manufacturer

  • 제조사 주소
    Synthes USA (HQ), Inc., 1302 Wrights Ln E, West Chester PA 19380-3417