Device Recall Axle Interspinous Fusion System Torque Driver Handle 의 리콜

U.S. Food and Drug Administration에 따르면, 해당 리콜 는 United States 에서 X Spine Systems Inc 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

의료기기에 문제가 생겼을 경우 제조사가 이를 바로잡거나 시장에서 회수하는 조치를 말한다. 회수(Recall)는 의료기기에 결함이 있거나, 건강에 위협이 되거나, 또는 결함도 있고 건강에도 위협이 될 경우에 발생한다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Recall
  • 사례 ID
    59756
  • 사례 위험등급
    Class 2
  • 사례 연번
    Z-0034-2012
  • 사례 시작날짜
    2011-07-15
  • 사례 출판 날짜
    2011-10-11
  • 사례 상황
    Terminated
  • 사례 국가
  • 사례 종료 날짜
    2013-03-01
  • 사례 출처
    USFDA
  • 사례 출처 URL
  • 비고 / 경고
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • 데이터 추가 비고
    General and plastic surgery - Product Code FZS
  • 원인
    The firm learned that the torque driver handles were not actuating at a proper torque. it was determined that the handles were speed determinant and could output a higher torque if the handles were turned at a very slow speed.
  • 조치
    X-spine Systems, Inc. sent an URGENT DEVICE RECALL letter dated September 12, 2011, to all affected customers. The letter identified the product, the problem, and the action to be taken by the customer. Customers were instructed to examine their stock immediately to determine if they have any affected product. If so, customers were instructed once the set screw is tightened onto the locking plate, and resistance is detected in the handle, it will take less than 2 seconds to hear the handle "click." The "click" indicates the torque limit was reached. If further resistance is felt after 2 seconds, the surgeon should release the handle from tension, and try again. If the product was distributed further, they should contact their accounts, and advise them of this recall. The firm will send replacement handles. For any questions call (937) 847-8400, ext 115.

Device

  • 모델명 / 제조번호(시리얼번호)
    Model #: X060-0323, Lot # 525941, S/Ns 001-017, Lot # 525942, S/Ns 001-050
  • 의료기기 분류등급
  • 의료기기 등급
    1
  • 이식된 장치?
    No
  • 유통
    Nationwide Distribution including CA, CO, FL, IA, IN, LA, NY, PA, TN, TX and UT.
  • 제품 설명
    Axle Interspinous Fusion System Torque Driver Handle, Model #: X060-0323, Lot # 525941, S/Ns 001-017, Lot # 525942, S/Ns 001-050, Mfr. By: Bradshaw Medical Inc., Kenosha, WI 53144 || The Axle Torque Driver Handle is used to lock the set screw into the locking plate.
  • Manufacturer

Manufacturer

  • 제조사 주소
    X Spine Systems Inc, 452 Alexandersville Rd, Miamisburg OH 45342-3658
  • 제조사 모회사 (2017)
  • Source
    USFDA