Sorin Group Italia SRL - CRF

데이터베이스에서 발견된 의료기기 1건 데이터베이스에서 발견된 의료기기 9 건

  • 모델명 / 제조번호(시리얼번호)
    All Serial Numbers
  • 의료기기 분류등급
  • 의료기기 등급
    3
  • 이식된 장치?
    Yes
  • 유통
    US Nationwide Distribution
  • 제품 설명
    Platinium VR 1210, Model Number TDF031U, UDI/GTIN 08031527015514, Implantable cardioverter defibrillator, || Biventricular or ventricular antitachycardia pacing, || Dual or single chamber arrhythmia detection || Product Usage: || PLATINIUM VR is indicated for use in patients who are at high risk of sudden cardiac death due to ventricular tachyarrhythmias and who have experienced one of the following situations: - Survival of at least one episode of cardiac arrest (manifested by the loss of consciousness) due to ventricular tachyarrhythmia, - Recurrent, poorly tolerated sustained ventricular tachycardia (VT).
  • 모델명 / 제조번호(시리얼번호)
    All Serial Numbers
  • 의료기기 분류등급
  • 의료기기 등급
    3
  • 이식된 장치?
    Yes
  • 유통
    US Nationwide Distribution
  • 제품 설명
    Platinium DR 1510, Model Number TDF032U, UDI/GTIN 08031527015521, Implantable cardioverter defibrillator, || Biventricular or ventricular antitachycardia pacing, || Dual or single chamber arrhythmia detection || Product Usage: || PLATINIUM VR is indicated for use in patients who are at high risk of sudden cardiac death due to ventricular tachyarrhythmias and who have experienced one of the following situations: - Survival of at least one episode of cardiac arrest (manifested by the loss of consciousness) due to ventricular tachyarrhythmia, - Recurrent, poorly tolerated sustained ventricular tachycardia (VT).
  • 모델명 / 제조번호(시리얼번호)
    All Serial Numbers
  • 의료기기 분류등급
  • 의료기기 등급
    3
  • 이식된 장치?
    Yes
  • 유통
    US Nationwide Distribution
  • 제품 설명
    Platinium CRT DF1 1711, Model Number TDF033U, UDI/GTIN 08031527015538, Implantable cardioverter defibrillator, || Biventricular or ventricular antitachycardia pacing, || Dual or single chamber arrhythmia detection || Product Usage: || PLATINIUM VR is indicated for use in patients who are at high risk of sudden cardiac death due to ventricular tachyarrhythmias and who have experienced one of the following situations: - Survival of at least one episode of cardiac arrest (manifested by the loss of consciousness) due to ventricular tachyarrhythmia, - Recurrent, poorly tolerated sustained ventricular tachycardia (VT).
  • 모델명 / 제조번호(시리얼번호)
    All Serial Numbers
  • 의료기기 분류등급
  • 의료기기 등급
    3
  • 이식된 장치?
    Yes
  • 유통
    US Nationwide Distribution
  • 제품 설명
    Platinium VR DF4 1240, Model Number TDF035U, UDI/GTIN 08031527015460, Implantable cardioverter defibrillator, || Biventricular or ventricular antitachycardia pacing, || Dual or single chamber arrhythmia detection || Product Usage: || PLATINIUM VR is indicated for use in patients who are at high risk of sudden cardiac death due to ventricular tachyarrhythmias and who have experienced one of the following situations: - Survival of at least one episode of cardiac arrest (manifested by the loss of consciousness) due to ventricular tachyarrhythmia, - Recurrent, poorly tolerated sustained ventricular tachycardia (VT).
  • 모델명 / 제조번호(시리얼번호)
    All Serial Numbers
  • 의료기기 분류등급
  • 의료기기 등급
    3
  • 이식된 장치?
    Yes
  • 유통
    US Nationwide Distribution
  • 제품 설명
    Platinium DR DF4 1540, Model Number TDF036U, UDI/GTIN 08031527015477, Implantable cardioverter defibrillator, || Biventricular or ventricular antitachycardia pacing, || Dual or single chamber arrhythmia detection || Product Usage: || PLATINIUM VR is indicated for use in patients who are at high risk of sudden cardiac death due to ventricular tachyarrhythmias and who have experienced one of the following situations: - Survival of at least one episode of cardiac arrest (manifested by the loss of consciousness) due to ventricular tachyarrhythmia, - Recurrent, poorly tolerated sustained ventricular tachycardia (VT).
하나 더 4 건 더