“The safety of patients has always been, and continues to be, Zimmer Biomet’s top priority and it is our honor to be a leader in this industry for the past 90 years,” Zimmer Biomet told ICIJ in a statement. “We adhere to strict regulatory standards, and work closely with the FDA and all applicable regulatory agencies in each of our regions as part of our commitment to operating a first-rate quality management system across our global manufacturing network. The company added that it is focused on staying at the forefront of innovation and doing right by the millions of patients who rely on the company’s products.
Zimmer Spine ST360 Distal Thread Reduction Guide Pins, Part number: 07.00684.00. Non-Sterile. Zimmer Spine, Inc., 7375 Bush Lake Road, Minneapolis, MN 55439 U.S.A. The Distal Thread Reduction Guide Pin is a reusable instrument that is part of a set of instruments used to perform reduction surgeries with the ST360 Spinal Fixation System. The ST360 Spinal Fixation System is a temporary implant system used to correct spinal deformity and facilitate the biological process of spinal fusion. This system is intended for posterior use in the thoracic, lumbar and sacral areas of the spine. Implants of this system consist of hooks and/or screws connected to rods and are intended to be removed after solid fusion has occurred. This system includes polyaxial screws of varying diameters and lengths, fixed screws of varying diameters and lengths, rods in varying lengths, hooks in varying designs, fixed and adjustable transverse connectors.
The product was shipped to Hawaii, New York, South Carolina, and South Dakota in the United States.
제품 설명
Trinica Bone Tap Instrument, Catalog Number 07.00168.001, sold separately and as part of Zimmer Spine Trinica Anterior Cervical Plating Instrument sets (catalog numbers 07.00215.001 and 07.00546.001). Only the Trinica Bone Tap Instruments are being recalled from the sets.
US (nationwide)-including the states of AL, AZ, AR, CA, CO, FL, GA, ID, IL, IN, IA, LA, ,MD, MA, MI, MN,MO, NV, NH, NY, NC, OH, OK,. PA, TN,TX, WA, and WI.
제품 설명
Instinct¿ Java¿ System (IFU reference: 046WAN0000T) . || Stabilizes one or more vertebral segments from the thoracic spine to the sacrum during the development of bone tissue.
US (nationwide)-including the states of AL, AZ, AR, CA, CO, FL, GA, ID, IL, IN, IA, LA, ,MD, MA, MI, MN,MO, NV, NH, NY, NC, OH, OK,. PA, TN,TX, WA, and WI.
제품 설명
Universal Clamp¿ System (IFU reference: SNA027-N-90001). || Provides the stability required for solid bone fusion and helps reduce spinal deformities and fractures.